Complete the adjustment after 3 seconds, the operation panel will return to original condition; welding current LED
(L4) is on. If the welding mode is TIG and the output pulse function is turned on, the pulse pilot light (L11) is on. If
the output pulse function is turned off, the pulse pilot light (L11) is off. In MMA mode, the pulse pilot light (L11) is
off. All preset parameters with hold function.
If the parameter indicator lights up, then the selected parameter can be altered on adjusting dial.
Available parameters where 2T and 4T mode have been selected:
Gas pre-flow time
Unit
S
Setting range 0.1—1
Factory setting
Starting current (only with 4T)
Unit
A
Setting range
5—100%of main current Iw
Factory setting
Upslope time
Unit
S
Setting range 0—5
Factory setting
Welding current
Unit
A
Setting range 5—200
;
Press the
‘selection knob’
again,
the output pulse function
is turned off.