Changes
- C215 order code updated to include the option for conformal coating.
- Icol> function's Operating time settings updated.
- Terminology consistency improved (e.g. binary inputs are now always called digital inputs).
- Tech data modified to be more informative about what type of measurement inputs are used (phase
currents/voltages, residual currents/voltages), what component of that measurement is available (RMS,
TRMS, peak-to-peak) and possible calculated measurement values (powers, impedances, angles etc.).
- Tech data updated: non-directional overcurrent
- Tech data updated: non-directional earthfault
- Tech data updated: current unbalance
- Improvements to many drawings and formula images.
- Improved and updated IED user interface display images.
- AQ-C215 Functions included list Added: Capacitor bank protection module, capacitor bank overload
protection, voltage memory and programmable stage.
- Added 6th harmonic to harmonic overcurrent protection function.
- Changed disturbance recorder maximum digital channel amount from 32 to 95.
- Added residual current coarse and fine measurement data to disturbance recorder description.
- HSO1 and HSO2 connection swapped in arc protection card (was way wrong before).
- Updated I01 and I02 rated current range.
- Added inches to Dimensions and installation chapter.
- Added raising frames, wall mounting bracket, combiflex frame to order code.
- Added logical input and logical output function descriptions.
- Additions to Abbreviations chapter.
- Added button test description to Local panel structure chapter.
- Added Fault register view to Basic configuration chapter.
- Added parameter descriptions to General menu IED user interface chapter.
- Protection IED user interface chapter almost completely rewritten and restructured.
- Added new parameter descriptions to Monitoring menu IED user interface chapter.
- Added note to Configuring user levels and passwords chapter that user level with a password
automatically locks itself after 30 minutes of inactivity.
- Added more "Tripped stage" indications and fault types to Measurement value recorder function.
- Updated: Digital input activation and release threshold setting ranges and added drop-off delay
setting.
- Added sample rate to voltage and current measurement tech data.
- Added double wye bank connection example to "Application example and its connections" topic.
- Fixed overvoltage, undervoltage, neutral overvoltage and sequence voltage stage misspelled IDMT
curve formula.
Revision
2.04
Date
8.6.2021
Changes
- Increased the consistency in terminology
- Various image upgrades
- Visual update to the order codes
A
AQ
Q-C215
-C215
Instruction manual
Version: 2.07
© Arcteq Relays Ltd
IM00040