Changes
- Terminology consistency improved (e.g. binary inputs are now always called digital inputs).
- Tech data modified to be more informative about what type of measurement inputs are used (phase
currents/voltages, residual currents/voltages), what component of that measurement is available (RMS,
TRMS, peak-to-peak) and possible calculated measurement values (powers, impedances, angles etc.).
- Tech data updated: non-directional overcurrent
- Tech data updated: non-directional earthfault
- Tech data updated: directional earthfault
- Tech data updated: current unbalance
- Tech data updated: transformer differential
- Tech data updated: overfrequency, underfrequency and rate-of-change-of-frequency.
- Improvements to many drawings and formula images.
- AQ-M257 Functions included list Added: Power factor protection, motor status monitoring, voltage
memory, indicator objects, vector jump protection, another instance of CTS, running hour counterv and
measurement recorder.
- Added "32N" ANSI code to directional earth fault protection modes "unearthed" and "petersen coil
grounded".
- Added 6th harmonic to harmonic overcurrent protection function.
- Fixed reset ratio of under- and overfrequency protection function from 103 % / 97 % to +/- 20 mHz..
- Fixed reset ratio of rate-of-change-of-frequency protection function from 20 mHz/s to 100 mHz/s.
- Changed disturbance recorder maximum digital channel amount from 32 to 95.
- Added residual current coarse and fine measurement data to disturbance recorder description.
- Event read mode parameter added to Modbus description.
- HSO1 and HSO2 connection swapped in arc protection card (was way wrong before).
- Updated I01 and I02 rated current range.
- Added inches to Dimensions and installation chapter.
- Added raising frames, wall mounting bracket, combiflex frame to order code.
- Added logical input and logical output function descriptions.
- Additions to Abbreviations chapter.
- Added button test description to Local panel structure chapter.
- Added note to Configuring user levels and passwords chapter that AQ-250 frame units generate a
time-stamped event from locking and unlocking user levels.
- Added note to Configuring user levels and passwords chapter that user level with a password
automatically locks itself after 30 minutes of inactivity.
- Added more "Tripped stage" indications and fault types to Measurement value recorder function.
- Updated: Digital input activation and release threshold setting ranges and added drop-off delay
setting.
- Added sample rate to voltage and current measurement tech data.
- Fixed overvoltage, undervoltage, neutral overvoltage and sequence voltage stage misspelled IDMT
curve formula.
- Z< removed from the Connections images.
- Note added to power protection tech data.