Event Number
Event channel
Event block name
Event Code
Description
9869
154
OBJ10
13
Close Request OFF
9870
154
OBJ10
14
Close Command ON
9871
154
OBJ10
15
Close Command OFF
9872
154
OBJ10
16
Open Blocked ON
9873
154
OBJ10
17
Open Blocked OFF
9874
154
OBJ10
18
Close Blocked ON
9875
154
OBJ10
19
Close Blocked OFF
9876
154
OBJ10
20
Object Ready
9877
154
OBJ10
21
Object Not Ready
9878
154
OBJ10
22
Sync Ok
9879
154
OBJ10
23
Sync Not Ok
9880
154
OBJ10
24
Open Command Fail
9881
154
OBJ10
25
Close Command Fail
9882
154
OBJ10
26
Final trip ON
9883
154
OBJ10
27
Final trip OFF
Table. 5.4.2 - 66. Register content.
Name
Description
Date and time
dd.mm.yyyy hh:mm:ss.mss
Event code
2944-9883 Descr.
Recorded Object opening
time
Time difference between the object receiving an "Open" command and the object receiving the
"Open" status.
Recorded Object closing
time
Time difference between the object receiving a "Close" command and object receiving the
"Closed" status.
Object status
The status of the object.
WD status
The status of the withdrawable circuit breaker.
Open fail
The cause of an "Open" command's failure.
Close fail
The cause of a "Close" command's failure.
Open command
The source of an "Open" command.
Close command
The source of an "Open" command.
General status
The general status of the function.
5.4.3 Indicator object monitoring
The indicator object monitoring function takes care of the status monitoring of disconnectors. The
function's sole purpose is indication and does not therefore have any control functionality. To control
circuit breakers and/or disconnectors, please use the Object control and monitoring function. The
monitoring is based on the statuses of the configured relay's digital inputs. The number of monitored
indicators in a relay depends on the device type and available inputs. The status monitoring of one
monitored object usually requires two (2) digital inputs. Alternatively, object status monitoring can be
performed with a single digital input: the input's active state and its zero state (switched to 1 with a
NOT gate in the Logic editor).
A
AQ
Q-S215
-S215
Instruction manual
Version: 2.04
138
Summary of Contents for AQ-S215