5-5
5
6. Install the sensor and tighten securely.
7. Connect the leads.
Fan Motor
RESISTANCE
(Fan Motor Connector)
1. Set the meter selector to the OHMS position.
2. Connect the red tester lead to the red wire; then con-
nect the black tester lead to the black wire.
PR183A
3. The meter must show less than 1 ohm.
NOTE: If the meter shows more than 1 ohm of resis-
tance, troubleshoot or replace the fan motor.
NOTE: To determine if the fan motor is good, con-
nect the red wire from the fan connector to a 12 volt
battery; then connect the black wire from the fan con-
nector to ground. The fan should operate.
Power Distribution
Module (PDM)
FUSES
The fuses are located in a power distribution module
under the operator’s seat. If there is any type of electrical
system failure, always check the fuses first.
1. Remove a fuse from the power distribution module.
NOTE: To remove the fuse, compress the locking
tabs on either side of the fuse case and lift out.
2. Set the meter selector to the DC Voltage position.
3. Connect the black tester lead to ground.
4. Using the red tester lead, contact each end of the fuse
holder connector terminals individually.
5. The meter must show battery voltage from one side
of the connector terminal ends.
NOTE: Battery voltage will be indicated from only
one side of the fuse holder connector terminal; the
other side will show no voltage.
NOTE: When testing the HI fuse holder, the head-
light OFF/HI/LO switch must be in the HI position;
when testing the LIGHTS fuse holder, the headlight
dimmer switch can be in either the HI or LO position.
NOTE: If the meter shows no battery voltage, trou-
bleshoot the battery, switches, power distribution
module, or the main wiring harness.
XTX
2411-886
XT/XTZ
2411-213
1. Set the meter selector to the OHMS position.
2. Connect the red tester lead to one spade end of the
fuse; then connect the black tester lead to the other
spade end.
3. The meter must show less than 1 ohm resistance. If
the meter shows open, replace the fuse.
NOTE: Make sure the fuses are returned to their
proper position according to amperage. Refer to the
amperage listed under each fuse on the power distri-
bution module.
RELAYS
The 4-pin relays are indentical plug-in type located on
the power distribution module. Relay function can be
checked by switching relay positions. The 4-pin relays
are interchangeable.
NOTE: The module and wiring harness are not a
serviceable component and must be replaced as an
assembly.
! WARNING
Care should be taken to keep clear of the fan blades.
CAUTION
Always replace a blown fuse with a fuse of the same
type and rating.