background image

12

Wall Sleeve Brands:

Top View

Rear Louvers

7

60

60

#1  Emerson                              15  Deep

1. Redirect the louvers at the back of the wall

sleeve as shown in the illustration. The use
of pliers is recommended.

2. Attach(1)1   x3/8 x25  long seal in the center at

the top of the sleeve. Remove the backing paper
and press into position.

3. Attach the (2) 1   x3/8  x14   long seals to the

left and right sides of the sleeve.

4.  Cut the 1    x3/8  x25  long seal to 14  long, and

attach it to the vertical section of the rear grille
as shown.

5. Attach (2)4   x3    x1    centering/support blocks

one on each side wall. Place in center of side

wall with the tapered end facing the opening.

6. Gently slide unit into sleeve.
7. Before sliding all-the-way back, remove 2nd

screw from front on left side of unit.

8. Remove the plastic washer from the screw.
9. Screw and attach the other end of the ground

wire to the unit as shown in picture. Make sure
that the toothed washer is against the cabinet.

10.Slide the unit completely to the rear to ensure

a good seal, making sure the ground wire does
not become tangled.

11.Seal & Frame the unit as described on the last

page of these instructions.

1

/

2

1

/

2

1

/

2

1

/

2

1

/

2

1

/

2

Meijer.com

Summary of Contents for KSTAT12-1A

Page 1: ...KSTAT12 1A KSTAT12 2A Meijer com...

Page 2: ...Producto Meijer com...

Page 3: ...1 866 747 4332 1 866 747 4332 Meijer com...

Page 4: ...unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensu...

Page 5: ...may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It may cause fire and elect...

Page 6: ...pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not sing the unit for...

Page 7: ...e power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire Please refer to the section Operation of Current Device for details In the event t...

Page 8: ...during normal operation may cause pinging or switching sounds Before you begin thoroughly familiarize yourself with the control panel and remote as shown below and all its functions then follow the s...

Page 9: ...Meijer com...

Page 10: ...temperature as in the cooling mode TO USE THE ENERGY SAVER FEATURE Press the button DO THIS In this mode the fan will continue to run for 3 minutes after the compressor shuts off The fan then cycles...

Page 11: ...FOLLOW ME S Follow Me Follow Me Follow Me Follow Me Meijer com...

Page 12: ...1 2 86 Meijer com...

Page 13: ...ioner from wall sleeve and prepare wall sleeve as follows Clean interior do not disturb seals Wall sleeve must be securely fastened in wall before installing Air Conditioner Drive more nails or screws...

Page 14: ...ons at the beginning of each section If this proves too difficult to accomplish 1 Remove the existing grille 2 Place the included aluminum grille towards the rear of the unit 3 Mark through the hole p...

Page 15: ...grille as shown 5 Attach 2 4 x3 x1 centering support blocks one on each side wall Place in center of side wall with the tapered end facing the opening 6 Gently slide unit into sleeve 7 Before sliding...

Page 16: ...eal in the center at the top of the sleeve Remove the backing paper and press into position 6 Attach 2 1 x3 8 x14 seals to the left and right sides of the sleeve 7 Cut the 1 x3 8 x25 long seal to 14 l...

Page 17: ...eal in the center at the top of the sleeve Remove the backing paper and press into position 6 Attach 2 1 x3 8 x14 seals to the left and right sides of the sleeve 7 Cut the 1 x3 8 x25 long seal to 14 l...

Page 18: ...ft and right sides of the sleeve 6 Cut the 1 x3 8 x25 long seal to 14 long and attach it to the vertical section of the rear grille as shown 7 Center unit and gently slide unit into sleeve 8 Before sl...

Page 19: ...cking paper and press into position 5 Attach 2 1 x3 8 x14 seals to the left and right sides of the sleeve 6 Cut the 1 x3 8 x25 long seal to 14 long and attach it to the vertical section of the rear gr...

Page 20: ...of the sleeve 6 Cut the 1 x3 8 x25 long seal to 14 long and attach it to the vertical section of the rear grille as shown 7 Center unit and gently slide unit into sleeve 8 Before sliding all the way...

Page 21: ...ks with the slot overlapping the seal above 10 Install the divider into the slots of the foam blocks You may need to trim the length to size 11 Cut the 1 x1 x25 seal to fit the top of the sleeve The p...

Page 22: ...x25 long seal in the center at the top of the sleeve Remove the backing paper and press into position 3 Attach 2 1 x3 8 x14 seals to the left and right sides of the sleeve 4 Cut the 1 x3 4 x14 long s...

Page 23: ...lush 13 Center unit and gently slide unit into sleeve 14 Before sliding all the way back remove 1st screw from front on left side of unit 15 Remove the plastic washer from the screw 16 Screw and attac...

Page 24: ...wall sleeve and the unit A flat bladed screwdriver or putty knife is recommended 1 2 2 Assemble the trim frame by inserting top and bottom pieces into side pieces and snapping into place 3 Pull cord...

Page 25: ...Never use hot water over 40 C 104 F to clean the air filter Never attempt to operate the unit without the air filter Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet...

Page 26: ...Control ON and set to desired setting O O O O Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front Outdoor temperature below 17 C 62 F To defrost the coil s...

Page 27: ...rmal during excessively humid days Remote Sensing Deactivating Prematurely some models Remote control not located within range Place remote control within 20 feet 180 radius of the front of the unit R...

Page 28: ...Two 3 RD TWO 1 866 747 4332 Third C Meijer com...

Reviews: