background image

!

CAUTION

When the air filter is to be
removed, do not touch the
metal parts of the unit.

It may cause an injury.

Do not clean unit when
power is on as it may cause
fire and electric shock, it may
cause an injury.

Operation with windows
opened may cause wetting
of indoor and soaking of
household furniture.

When the unit is to be
cleaned, switch off, and turn
off the circuit breaker.

Stop operation and close
the window in storm or
hurricane.

Use caution when unpacking and
installing. Sharp edges could cause injury.

Do not clean the air
conditioner with water.

Water may enter the unit and
degrade the insulation. It may
cause an electric shock.

This could injure the pet or
plant.

It may cause electric shock
and damage.

Do not put a pet or house
plant where it will be
exposed to direct air flow.

Hold the plug by the head
of the power plug when
taking it out.

Ventilate the room well when
used together with a stove,
etc.

An oxygen shortage may occur.

Do not use this air conditioner to

preserve precision devices, food,

pets, plants, and art objects.

It may cause deterioration of

quality, etc.

It may cause failure of product

or fire.

Do not use for special
purposes.

Turn off the main power
switch when not sing the
unit for a long time.

u

If water enters the unit, turn the unit off at the power
outlet and switch off the circuit breaker. Isolate
supply by taking the power-plug out and contact a
qualified service technician.

3

!

!

!

!

!

!

!

It may cause failure of
appliance or accident.

Appearance may be
deteriorated due to change
of product color or
scratching of its surface.

Do not place obstacles
around air-inlets or inside
of air-outlet.

Do not use strong deter-
gent such as wax or
thinner but use a soft cloth.

If bracket is damaged, there
is concern of damage due to
falling of unit.

There is danger of fire or
electric shock.

Ensure that the installation bracket of
the outdoor appliance is not damaged
due to prolonged exposure.

Do not place heavy object on the
power cord and ensure that the cord
is not compressed.

Operation without filters may

cause failure.

It contains contaminants and

could make you sick.

Always insert the filters
securely. Clean filter once
every two weeks.

Do not drink water drained
from air conditioner.

!

!

Meijer.com

Summary of Contents for KSTAT12-1A

Page 1: ...KSTAT12 1A KSTAT12 2A Meijer com...

Page 2: ...Producto Meijer com...

Page 3: ...1 866 747 4332 1 866 747 4332 Meijer com...

Page 4: ...unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensu...

Page 5: ...may cause explosion fire and burns It may cause electric shock or fire due to heat generation It may cause electric shock It may cause failure of machine or electric shock It may cause fire and elect...

Page 6: ...pets plants and art objects It may cause deterioration of quality etc It may cause failure of product or fire Do not use for special purposes Turn off the main power switch when not sing the unit for...

Page 7: ...e power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire Please refer to the section Operation of Current Device for details In the event t...

Page 8: ...during normal operation may cause pinging or switching sounds Before you begin thoroughly familiarize yourself with the control panel and remote as shown below and all its functions then follow the s...

Page 9: ...Meijer com...

Page 10: ...temperature as in the cooling mode TO USE THE ENERGY SAVER FEATURE Press the button DO THIS In this mode the fan will continue to run for 3 minutes after the compressor shuts off The fan then cycles...

Page 11: ...FOLLOW ME S Follow Me Follow Me Follow Me Follow Me Meijer com...

Page 12: ...1 2 86 Meijer com...

Page 13: ...ioner from wall sleeve and prepare wall sleeve as follows Clean interior do not disturb seals Wall sleeve must be securely fastened in wall before installing Air Conditioner Drive more nails or screws...

Page 14: ...ons at the beginning of each section If this proves too difficult to accomplish 1 Remove the existing grille 2 Place the included aluminum grille towards the rear of the unit 3 Mark through the hole p...

Page 15: ...grille as shown 5 Attach 2 4 x3 x1 centering support blocks one on each side wall Place in center of side wall with the tapered end facing the opening 6 Gently slide unit into sleeve 7 Before sliding...

Page 16: ...eal in the center at the top of the sleeve Remove the backing paper and press into position 6 Attach 2 1 x3 8 x14 seals to the left and right sides of the sleeve 7 Cut the 1 x3 8 x25 long seal to 14 l...

Page 17: ...eal in the center at the top of the sleeve Remove the backing paper and press into position 6 Attach 2 1 x3 8 x14 seals to the left and right sides of the sleeve 7 Cut the 1 x3 8 x25 long seal to 14 l...

Page 18: ...ft and right sides of the sleeve 6 Cut the 1 x3 8 x25 long seal to 14 long and attach it to the vertical section of the rear grille as shown 7 Center unit and gently slide unit into sleeve 8 Before sl...

Page 19: ...cking paper and press into position 5 Attach 2 1 x3 8 x14 seals to the left and right sides of the sleeve 6 Cut the 1 x3 8 x25 long seal to 14 long and attach it to the vertical section of the rear gr...

Page 20: ...of the sleeve 6 Cut the 1 x3 8 x25 long seal to 14 long and attach it to the vertical section of the rear grille as shown 7 Center unit and gently slide unit into sleeve 8 Before sliding all the way...

Page 21: ...ks with the slot overlapping the seal above 10 Install the divider into the slots of the foam blocks You may need to trim the length to size 11 Cut the 1 x1 x25 seal to fit the top of the sleeve The p...

Page 22: ...x25 long seal in the center at the top of the sleeve Remove the backing paper and press into position 3 Attach 2 1 x3 8 x14 seals to the left and right sides of the sleeve 4 Cut the 1 x3 4 x14 long s...

Page 23: ...lush 13 Center unit and gently slide unit into sleeve 14 Before sliding all the way back remove 1st screw from front on left side of unit 15 Remove the plastic washer from the screw 16 Screw and attac...

Page 24: ...wall sleeve and the unit A flat bladed screwdriver or putty knife is recommended 1 2 2 Assemble the trim frame by inserting top and bottom pieces into side pieces and snapping into place 3 Pull cord...

Page 25: ...Never use hot water over 40 C 104 F to clean the air filter Never attempt to operate the unit without the air filter Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet...

Page 26: ...Control ON and set to desired setting O O O O Air conditioner cooling but room is too warm ice forming on cooling coil behind decorative front Outdoor temperature below 17 C 62 F To defrost the coil s...

Page 27: ...rmal during excessively humid days Remote Sensing Deactivating Prematurely some models Remote control not located within range Place remote control within 20 feet 180 radius of the front of the unit R...

Page 28: ...Two 3 RD TWO 1 866 747 4332 Third C Meijer com...