Arctic Essentials Owners Manual
27
9õ3ERIESõ4ECH"OOK
)FõTHEõOZONATORõISõNOTõWORKINGõ
FOLLOWõTHISõTROUBLESHOOTINGõmOWõCHART
3TEPBY3TEP
/ZONATORõDOESNgTõWORK
õõmOWõCHARTõõSTEPBYSTEP
(ASõ
-PS[LY*`JSL
õ
INDICATORõ
APPEAREDõSTEADYõ
ONõKEYPADõ
DISPLAY
YES
NO
3TARTõUPõAõõ
lLTERõCYCLE
YES
$OõYOUõREADõõ
õ6õFORõAõõ
õ6õOZONATORõ
ORõõ6õFORõõ
6 õONõõ
THEõBOARD
NO
YES
)Sõ0UMPõõ
WORKING
2EPLACEõSPAõPACKõ
IFõYOUõSTILLõARENTõ
GETTINGõAõVOLTAGEõ
READING
NO
2EFERõTOõh
Pump 1
does not Work!
võ
SECTION
&LOWõCHART
/ZONATORõOUTPUTõWILLõBEõSHUTõDOWNõWHENõ0UMPõõ0UMPõõORõBLOWERõHAVEõBEENõTURNEDõONõMANUALLY
)FõTHEõOZONATORõISõNOTõ
WORKING
sõ #HECKõIFõ&ILTERõ#YCLEõ
INDICATORõAPPEARSõ
STEADYõONõKEYPAD
sõ )FõTHEõlLTERõINDICATORõ
ISõBLINKINGõITõINDICATESõ
THATõTHEõlLTERõCYCLEõHASõ
BEENõINTERRUPTEDõõ
)NõTHATõCASEõRESETõTHEõ
BREAKERõBYõTURNINGõTHEõ
POWERõOFFõANDõONõAGAINõ
TOõRESUMEõCYCLE
sõ )FõNOTõSTARTõUPõAõ
lLTERõCYCLEõSEEõ
0ROGRAMMINGõ&ILTERõ
#YCLESõSECTION
sõ )FõYOUõDONgTõGETõAõ
VOLTAGEõREADINGõ
REPLACEõTHEõACCESSORYõ
FUSE
sõ )FõCHANGINGõTHEõFUSEõ
DOESõNOTõlXõTHEõ
PROBLEMõREPLACEõTHEõ
SPAõPACK
sõ )FõVOLTAGEõISõASõITõSHOULDõ
BEõREPLACEõOZONATOR
sõ )FõOZONATORõDOESõNOTõ
WORKõEVENõWHENõlLTERõ
CYCLEõINDICATORõISõONõ
TAKEõVOLTAGEõREADINGõ
ONõTHEõCORRESPONDINGõ
!-0õCONNECTOR
õ 0INõõõ0INõ
õ 9OURõREADINGõSHOULDõ
BE
õ õ6õFORõ
õ Aõõ6õPUMP
õ õ6õFORõAõ
õ õ6õPUMP
0INõ
0INõ
/ZONATORõFUSEõ&
2EPLACE
OZONATOR
#HECKõ
WIRINGõANDõ
PLUGSõ
2EPLACEõIFõ
NEEDED