background image

 

 

 

 

 

 

 
15

Never put fingers or other objects in any openings 

of the unit. 

16

Care should be taken when using the unit, unplug 

the appliance during cleaning. 

13

Switch  off  and  unplug  the  unit,  empty  the  water 

reservoir when not using the unit for a long time. 

14

Do  not  pull  power  wire  by  force  because  it  will 

cause damage to power wire. 

 

 

 

 

 

 

 

 

 

Ambient Environment For Operating 

 
1. Working environment: 

Lowest ambient temperature 5

°

C, 40%RH. 

Highest ambient temperature 35

°

C, 90%RH. 

2. Operate the unit indoors, e.g. living room, bedroom, etc. Never use it in wet environment or 

outdoors. 

3. Make sure the door and window are closed before turning on the unit. 
4. Ensure that the unit is placed on a stable and flat floor surface. If the floor surface is not even 

there  is  a  risk  that  the  unit  may  be  unstable  and  topple  over.  Also  excessive  vibration  and 
noise may be result. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Fenja 10

Page 1: ...User s Manual Arctus Fenja 10...

Page 2: ...Functions of Control Panel Key Pads Operation of Key Pads Automatic Defrosting Water Full Processions Of Abnormal Compressor Protection Of Extremely Low High Temperature Failures Of Humidity Temperat...

Page 3: ...er pull the socket by using damp hands 2 To protect against electrical shock do not place it in near window or in bathroom 4 Never operate this unit in an explosive or corrosive atmosphere 6 Operate t...

Page 4: ...wire Ambient Environment For Operating 1 Working environment Lowest ambient temperature 5 C 40 RH Highest ambient temperature 35 C 90 RH 2 Operate the unit indoors e g living room bedroom etc Never u...

Page 5: ...Components Diagrams Air deflector Control panel...

Page 6: ...ower socket 2 beep signals can be heard all the indicators illuminate 1 minute and then go off automatically 2 Press the button to turn on the unit The appliance turns into constant dehumidifying and...

Page 7: ...the appliance auto defrosts the fan works at high speed 5 Press TIMER Press TIMER to timer power on off and set the working hour of units 1 Time reserved for operating When appliance is powered off or...

Page 8: ...voir must be removed to empty and reinstalled before the unit operates again The interval of dehumidifying lasts about 3 minutes because of the compressor s protection Processions Of Abnormal Compress...

Page 9: ...ng mode dehumidifying for 20 minutes then defrosting for 5 minutes 1 When the temperature sensor malfunctions the keys of control panel will performance normally 2 When the temperature sensor malfunct...

Page 10: ......

Page 11: ...Before any maintenance or cleaning please switch off and unplug the unit Before moving the unit please switch off and unplug the unit If not using the unit for a long time Please switch off and unplu...

Page 12: ...ted 220 240VAC 50Hz Moisture removal 10 L D 30 RH80 Dehumidifying Power 220W 30 RH80 Max Power Dissipation 240W 35 RH90 Dehumidifying Air Volume L 80m3 h H 100 m3 h Refrigerant R134a 125g Capacity of...

Reviews: