Failures Of Humidity & Temperature Sensor
1. When the connect wire of humidity and temperature sensor breaks off, the symbol of continuous
dehumidification
”
CON
”
will wink. The appliance comes into continuous dehumidifying mode.
1
)
When the temperature sensor malfunctions, the appliance will turn to continuous
dehumidification mode and not under control of humidity setting.
2
)
This malfunction will not influence the dehumidification.
2. When the temperature sensor of evaporator is open circuit or short circuit, the symbol of defrost will
wink and the appliance turns into given dehumidifying and defrosting mode: dehumidifying for 20
minutes, then defrosting for 5 minutes.
1
)
When the temperature sensor malfunctions, the keys of control panel will performance
normally.
2
)
When the temperature sensor malfunctions, the appliance will continue to work with lower
efficiency.
Memory Function
If power supply is cut off when the appliance is running, it will memorize the working mode
automatically. Once power restoration, the appliance will restart and continue this working mode.
1
)
The appliance will not keep memory function if manual & timing shutdown, the appliance will
restart to run in the original state, not recover back to the previous setting mode.
2
)
When the power supply is shut off in case of protection mode, the appliance will not recover
back to the previous setting mode.
Continuous Drainage
Remove water plug and connect with PVC hose with spigot.
PVC hose must be placed on the ground flatly.
Do not tangle the hose.
Do not immerse the end of water outlet into other receptacle to avoid water flow blocked.
!