4.4.2. Digital Outputs
In Pulse Mode, three digital outputs are designated as INPOS, ALARM outputs.
Third digital output is general purpose output.
In Control Mode, three digital outputs are available for general purpose use.
Figure 4.8 shows an example circuit of the digital outputs for TITAN-SVX-ETH
Figure 4.8
The DO_COM must be connected in order for the digital outputs to operate.
4.4.3 Digital Inputs
In Pulse Mode, the following digital inputs are available: Enable, Reset, and Clear.
Three other digital inputs are general purpose inputs.
In Control Mode, the following digital inputs are available: +Limit, Home, and -Limit.
Remaining 3 digital inputs are available for general purpose use. Note that in
Control Mode, limit inputs can be disabled and these limit inputs can be used as
general purpose inputs.
Figure 4.9 shows the detailed schematic of the opto-isolated digital inputs available
on the TITAN-SVX-ETH.
Figure 4.9
The DI_COM must be connected in order for the digital inputs to operate