background image

 
 

 

AMX32 

Summary of Contents for AMX32FE

Page 1: ...AMX32 ...

Page 2: ...Access Multiplexer with Fast Ethernet User Manual 1 AMX32FE Access Multiplexer with Fast Ethernet USER GUIDE ...

Page 3: ...escription of indicators 25 6 3 Description of LCD keys 26 6 4 Description of 4 RJ45 port 26 6 5 HyperTerminal CONSOLE CON 28 6 6 Description of button 29 6 7 PHONE at order wire phone interface optional 29 6 8 RESET 29 6 9 Power indicator 29 6 10 Back panel 30 6 11 Bottom Board Preset Holes 30 Chapter 7 Installation of Optical Multiplexer 32 7 1 Equipment Package and Appearance Check 32 7 2 Equip...

Page 4: ... of HyperTerminal at CONSOLE interface on the front panel 42 11 2 Utilization of HyperTerminal of CON interface on the front panel 49 Chapter 12 Typical Networking Scheme 55 Chapter 13 DB37 RJ45 120Ω Pin Definitions 56 I History Rev Date Author s Remarks 1 0 28 11 09 AZI Initial document 1 1 27 09 10 AZI Changes after Review ...

Page 5: ... to IEEE 802 3 and E1 interface complying with 16 channel standard At the same time it also provides sufficient network management interface function and realizes SNMP network management or device management via hyper terminal The device itself is supplied with a LCD displayer for user to carry out configuration and management The whole system adopts modularized structure 16 channels of 2M service...

Page 6: ... to adapt to this demand Chapter 2 System General Description T Th he e AMX32FE is created with 16E1 100M full speed Ethernet capacity of transmission interfaces The equipment also provides various interface modules for voice data and video services in cities and industrial districts Its optional interfaces support multiservice transmission of large customers and customer groups such as MSEs gover...

Page 7: ...ther but easy for assembly which enables it to derive a series of optical multiplexer products with multiservice interfaces The equipment is furnished with four modular slots According to the networking requirements of different users various kinds of interface modules can be 16 8 4 Channel E1 One Data Channel 378K One asynchronous Serial Interface 19 2 k Alarm and Control Module Multiplexing Inte...

Page 8: ...ing hot add drop of optical interface and fulfil switching without error code during hot add drop Flexible Configuration 4 8 12 16E1 optical multiplexers and multiservice interfaces are derivable from main system board and different functional modules to meet different user requirements and customizations Various Functional Modules User interface modules N 64K V 35 FV 35 FXO FXS E M RS232 RS485 an...

Page 9: ... outputs them through drive circuit in the end This unit compounds NRZ signals order wire services and alarms then encodes and output NRZ signals to drive laser and achieves the reverse process for the above mentioned part at the same time It can be plugged in 4 8 12 16 channels of E1 plug in board V 35 board or voice board etc according to the actual user requirements Optical Interface Unit is to...

Page 10: ...w version supports hot plugging swap of optical interface In the case that one optical interface runs into trouble the fault optical interface board can be drawn out online and replaced with a new one Network management Unit is designed to control all settings on the control panel and to realize communications between multiplexer and computer The unit can send commands such as alarm off remote byp...

Page 11: ...al pluggable interface boards a power switch module and a user interface card Order wire module network management module and alarm output module are also prepared for user selection The system is provided in a structure of 19 standard rack It can be used not only as the desktop device independently but also installed inside the 19 rack The equipment height is 1 2U 3 1 Motherboard 1 To achieve enc...

Page 12: ...3 Bit Rate 2 048Mbit s 50ppm Dual V 35 Interface Card Two channels of V 35 interface available Interface Electric Level In compliance with CCITT V 35 standard Physical Interface DB25 Interface Bit Rate 2 048Mbit s 4 Channel V 35 Interface Card 4 channels of V 35 Interface to be framed Interface Electric Level In Compliance with CCITT V 35 Standard Physical Interface DB37 Speed of Interface N 64Kbi...

Page 13: ...K bps Transmission Mode Full Duplex RS422 RS485 Interface Card Physical interface RJ45 Four RS422 RS485 transmission channels available Transmission Speed max 115 2K bps Transmitting Mode full half duplex Chapter 4 Technical Specifications 4 1 Electrical Interface 4E1 Interface Card Each card contains 4 E1 Interfaces 4xE1 In accordant with G 823 standard Interface Bit Rate 2 048 Mbit s 50 ppm Impe...

Page 14: ...modes of 75Ω unbalanced transmission and 120Ω balanced transmission are available Please specify one when ordering When unbalanced transmission mode is used please use 75Ω coaxial adapter joint as shown in the following figure Four standard G 703 signals 2048kbit s IN1 IN2 IN3 and IN4 are used to receive 4 input signals respectively and OUT1 OUT2 OUT3 and OUT4 are the 4 corresponding output signal...

Page 15: ...5 conversion line shall be provided It is used to butt connect with DTE port to convert DB25M into DB34F and can also be used for direct connection with DTE equipment If equipment needs to be connected with DCE device cross connection in DCE to DCE structure can be applied Please make it clear when placing order Provided that 2 V 35 card is plugged in the slot I on the mainboard the lower V 35 cha...

Page 16: ... respectively Provided that 2 V 35 card is plugged in the slot IV on the mainboard the lower V 35 channel and the upper V 35 channel may correspond to 13th and 14th indicators on the front panel respectively 4 2 Channel N 64k framing V 35 Interface Card Each card contains four two V 35 Interfaces 4 2 xFV 35 Physical interface is DB37 and if there is 4 channel V 35 interface card fitted in the equi...

Page 17: ... 16 The interface under double layer female DB37 interface card is the 1st and 2nd channels of V 35 and the interface above is the 3rd and 4th channels of V 35 Different pins of DM34 Needle Type Interface and DB37 Cellular Type are defined as follows ...

Page 18: ...dy DTE DCE 8 C Request for sending DTE DCE 9 Mm 10 Hh 11 Cc 12 Y Timing for sending code element of signal A DCE DTE 5 33 13 U Timing for terminal sending code element of signal A DTE DCE 22 13 14 P Sending data A DTE DCE 2 30 15 K Local loop test 16 E Data device ready DCE DTE 27 18 17 A Rack ground PGND 1 29 18 Ll 19 Ff 20 Bb 21 X Timing for receiving code element of signal B DCE DTE 25 16 22 T ...

Page 19: ...cted with DTE device When it is required for device to be connected with DCE device cross connection in DCE to DCE structure can be made through cross cable Please specify V 35M V 35M 0 5M when ordering adapter for connection in tail to tail structure Pin definitions for cross connection in tail to tail structure adapter V 35M V 35M 0 5M DB34 Needle A Function DB34 Needle B A Protective Ground A B...

Page 20: ...follows Note When V 35 time slot being configured to be 2M transparent transmission the command configuration of the remote V 35 E1 loop back will be ineffective 4 Pseudo random code test Local Remote Remote loop V 35 E1 Fiber E1 V 35 Schematic diagram of local V 35 E1 loop back Schematic diagram of remote V 35 E1 loop back Local Remote Master Clock Slave Clock V 35 Fiber V 35 Set pseudo random co...

Page 21: ...onfigured through network management interface including assignment of timeslots and clock setting etc The ex work default is 2M transparent transmission and can also be set as customized It can also be configured via hyper terminal or LCD See the relevant operation manual for details Typical Application Methods Attentions 1 It must be avoided that all devices use line clock If it can be V 35 C V ...

Page 22: ... FXS Voice Channel Interface Card Each card contains four or eight channels of FXO FXS interface 4 8 VOICE FXO Interface Card to provide FXO interface connected with switch FXS Interface Card to provide FXS interface connected with ordinary telephone set 1 DB9 hole Interface 2 RJ45 Interface 1 2 3 4 5 6 7 8 4 Channel FXO FXS Interface 1 2 The 1st Loop Audio 3 4 The 2nd Loop Audio 5 6 The 3rd Loop ...

Page 23: ...es providing 4 RS422 RS485 data ports The definitions of pins are as follows RS 422 Interface 8 7 6 and 5 as A R B R Z T and Y T respectively RS232 Interface Card PC RS232 Interface RJ45 DB9 TX 2 RX 3 GND 5 2 RX 3 TX 5 GND 8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1 8 Channel FXO FXS Interface Lower RJ45 1 2 The 1st Loop Audio 3 4 The 2nd Loop Audio 5 6 The 3rd Loop Audio 7 8 The 4th Loop Audi...

Page 24: ...smitting Distance 0 40 km 40 120 km to be customized Provide dual optical interface module allowing hot add drop fulfill optical interface switching without error code 4 3 Power Supply Quality module power supply is adopted to allow wide range of voltage fluctuation strong anti jamming capacity good isolation and stable performance Separate power supply modules of 220AC 5V DC 48V and 5V are suppli...

Page 25: ...mperature and operate normally and steadily in environmental extremes Operating Temperature 5 40 Storage Temperature 25 55 Relative Humidity 85 30 Atmospheric pressure 70 106 kPa No corrosive and solvent gas and free from flying dust and magnetic field interference Chapter 6 Function Description The peripheral interfaces of the AMX32FE can be divided into optical interface electrical interface mon...

Page 26: ...ical interface in working OPL Alarm indication of optical loss at the currently working optical interface flashing refers to the alarm occurs SYL indication of optical out of step at the currently working optical interface light on refers to the alarm occurs E3 indication of a system error code larger than 10 3 at the currently working optical interface light on refers to the alarm occurs E6 indic...

Page 27: ...f the 2nd Ethernet interface chain to be 10M or 100 M Light on refers to 100M off refers to 10M 6 3 Description of LCD keys The button L is used to exit to the upper level or quit configuration press the button R to enter the submenu The buttons U and D are used to select menus in the same level The button ENTER is used to parameter setting or confirmation of parameter setting 6 4 Description of 4...

Page 28: ...ctly for output Relay output alarm can effectively isolate the equipment and avoid the alarm disc from electrical interferences Electrical level output alarm Alarms are accompanied by output of local general alarm RJ45 4PIN and remote general alarm RJ45 2PIN Low electrical level will be found when there is alarm output and electrical level is 5V when there is no alarm output The equipment provides...

Page 29: ...other HyperTerminal Interface CONSOLE HyperTerminal software can be used for the interface To apply this interface to configure the equipment press the right switching button CONSOLE NM ETH at its left With CONSOLE NM ETH pushed down NM ETH Ethernet interface will disconnect with the equipment and the equipment will be off line That is to say if CONSOLE NM ETH pressed down the equipment will be of...

Page 30: ...ply a line of order wire phone to facilitate the connection between debug and maintenance equipments and the central equipment room Press the button CALL down to call the opposite end keep it pushed down during calling release the button CALL to hang up or hold on The definition of pins is as follows 6 8 RESET The button is a push button Being pressed once refers to reset the whole configuration B...

Page 31: ...ngular holes on the bottom board of equipment I When the plug in interface board is G 703 4 E1 interface board the switch is used as impedance match for E1 interface The switch is set up as per ordering instructions at the ex work time Attention External adapter must be corresponding 1 The 1st E1 2 The 2nd E1 3 The 3rd E1 4 The 4th E1 ON OFF ON OFF ON OFF ON OFF 75Ω 120Ω 75Ω 120Ω 75Ω 120Ω 75Ω 120Ω...

Page 32: ...ged in the switch is used for option of RS422 RS485 1 The 1st Interface 2 The 2nd Interface 3 The 3rd Interface 4 The 4th Interface ON OFF ON OFF ON OFF ON OFF RS485 RS422 RS485 RS422 RS485 RS422 RS485 RS422 IV When 2M Ethernet interface board is plugged in the switch is used for setting up watchdog and speed of Ethernet interface The 1st Switch ON Watchdog Disabled OFF Watchdog Enabled The 2nd Sw...

Page 33: ...ur Company at once if there is any serious damage for timely solutions 2 After the equipment is unpacked check it as per packing list Please contact the installers or the After Service Department of our Company directly if any damage is found with exterior of the machine frame for timely replacement 3 The equipments can only be used in pairs Consistent configuration must be guaranteed before they ...

Page 34: ...in tact 3 Protective grounds of the equipment and the equipment room should be well connected 4 Connect with optical fiber Check whether the end of optical fiber is clean first Insert the FC SC fiber jumper and then screw the fiber jacket gently radius of bending curvature of the fiber should be equal to or larger than 50mm 5 Connect signal cables in turn and then turn on all the branch alarm sign...

Page 35: ... ct t t to o i ir rr re em me ed di ia ab bl le e d da am ma ag ge es s 4 Optical connectors are not to be polluted and fiber optic splices shall be gently scrubbed with alcohol prior to use otherwise transmission effect would be influenced If optical connectors are not butt jointed and aligned properly it could lead to relative substantial power attenuation Pay attention to adjusting optical conn...

Page 36: ... the pushbutton of CONSOLE NM ETH on the panel shall be pushed down 8 3 Description about Application As in the example of 220V power supply 8 E1 8 V 35 one channel of Ethernet in 10M half duplex status Have the equipment installed and after confirming that power supply socket is well grounded proceed with operation as per following steps 1 Connect with 220 power supply 2 Ensure that the pushbutto...

Page 37: ... The equipment has been adjusted to the optimum state before leaving the factory All the functional interfaces are located on the front and rear panels Only professional technicians are allowed to open the enclosure with relevant approval 2 In the case the equipment runs into a fault analyze the possible cause based on the fault indicators otherwise self loop the single unit to determine the fault...

Page 38: ... electrical interface E1 or V 35 Note the making method of self loop connector for electrical interface E1 or V 35 3 Fault of optical interface Phenomenon Cause Diagnosis and solution Optical loss alarm at both ends If the self loop check at two ends are normal the transmission fiber optic connection is free of fault if the optical loss alarm remains the Replace the transmission fiber optic or che...

Page 39: ... telephone set or repair the order wire Note When measuring the optical power the ALS function shall be switched off Please refer to the ALS configuration of LCD part Chapter 10 Operation Manual of LCD 10 1 Description of menu system The key press L is used to go back to the upper menu or quit setting R to enter the submenu The key presses U and D are to select menus in the same level The key pres...

Page 40: ...r the setting succeeds or not When the screen displays the status of on the second line of the menu is the running status of the device The detailed operation flow chart of the menu system of Fiber Optic Multiplexer FOM is shown as follows MAINBOARD MENU SYSTEM Fiber OPic Multi PARAMETER INT BOARD 1 PARAMETER 4xE1 BOARD INT BOARD 2 PARAMETER 1 FV 35 PARAMETER INT BOARD 3 PARAMETER 1 FV 35 PARAMETE...

Page 41: ...EFAULT LOCAL MAIN OPT MODE AUTO OPT SWIT GRADE E3 E3 OPT ALS ON ON LOOP E1 1 16 ON E1 MASK OFF OFF ON OFF ETH 1 MODE AUTO 10M HALF DUP ETH 2 MODE AUTO AUTO 10M FULL DUP 100M HALF DUP 100M FULL DUP 10M HALF DUP AUTO 10M FULL DUP 100M HALF DUP 100M FULL DUP MUTE ON ON OFF LED DISP LOCAL LOCAL REMOTE SET DEFAULT SURE ON SAVE SET INFO LOCAL SAVE SET INFO SURE ON ...

Page 42: ... set the speed of the 4th channel of V 35 basic framing transmission i e PCM31 CCS on the 4th interface board 4xFV 35 interface board of the remote device to be 31 64 1984Kbps 1 Press L or R or U or D to enter LOCAL PARAMETER 2 Press U or D to enter REMOTE PARAMETER 3 Press R to enter MAINBOARD PARAMETER 4 Press U to enter INT BOARD 4 PARAMETER 5 Press R to enter 1 FV 35 PARAMETER 6 Press U to ent...

Page 43: ...ter TIMESLOT 16 31 17 Press R to move the cursor to the right and associatively use the key U or D to select or refers to select the time slot means not to select the time slot Use U or D to switch between and the setting result of time slot is TIMESLOT 16 31 18 Press ENTER again to enter TIMESLOT 16 31 the setting of 16 31 time slots is finished 19 Press the key L all the time to go back to the u...

Page 44: ...rly input help following the command prompt 5 If the set command is correct the device will return with a message O K In the case of query the queried information will be returned directly Provided with an incorrect command no message returns 6 The setting of PC HyperTerminal 19200bps 8 bit data bit 1 stop bit no parity bit flow control NO 7 The description of the button CONSOLE NM ETH being press...

Page 45: ...ds fv 35 to query the local fv 35 daughter board information of the device E g getlinfo 1 fv 35 refers to query the information of the first daughter board If the first daughter board is not fv 35 daughter board no response will occur 4 getrinfo 1 2 3 4 boards fv 35 to query the remote fv 35 daughter board information of the device E g getrinfo 1 fv 35 refers to query the information of the first ...

Page 46: ... refers to remote setl r mainsys space lop loop back space o f al For example setlmainsys lop o al to set the local all loopback setlmainsys lop f al to cancel all loopback of the local setrmainsys lop o al to set the remote all loopback setrmainsys lop f al to cancel all loopback of the remote setl r mainsys space msk to mask the unused E1 alarm o f ON or OFF E g setlmainsys msk o to set the loca...

Page 47: ...ptical interface A E g setlmainsys f a setrmainsys f a setl r mainsys space aut auto switching E g setlmainsys aut setrmainsys aut setl r mainsys space aut auto switching space a preferential switching E g setlmainsys aut a setrmainsys aut a setl r mainsys space grd auto switching grade space e 3 e3 error code switching E g setlmainsys grd e 3 setrmainsys grd e 3 setl r mainsys space grd auto swit...

Page 48: ...4 1 4 pieces of plugged boards space 1 4 1 4 channels of V 35 lop loop back space lvlo local v 35 loopback ON lvlf local v 35 loopback OFF rvlo remote v 35 loopback ON rvlf remote v 35 loopback OFF lelo local e1 loopback ON lelf local e1 loopback OFF relo remote e1 loopback ON relf remote e1 loopback OFF E g setlfv 35 1 1 lop lvlo E g setlfv 35 1 1 lop lelo setl r fv 35 space 1 4 1 4 pieces of plu...

Page 49: ...t the middle 8 timeslots of the first channel of the first plugged board FV 35 i e s23 s16 setlfv 35 1 1 slt 2 11110000 to set the lower 8 timeslots of the first channel of the first plugged board FV 35 i e s15 s8 setlfv 35 1 1 slt 1 11110000 to set the lowest 8 timeslots of the first channel of the first plugged board FV 35 i e s7 s0 Command to save the information setl r save save the local remo...

Page 50: ...age shall be corresponding to this 11 2 Utilization of HyperTerminal of CON interface on the front panel Function to configure the SNMP Ethernet interface NM ETH 11 2 1 The following operation shall be performed with the power being off 1 Prepare a RS 232 crossover line and connect it with the CON on the front panel 2 Open the configuration view of the HyperTerminal software as shown below 3 Switc...

Page 51: ... 3 Knock on the key ENTER within 5 6 seconds to enter the configuration interface otherwise linux will be started up to enter into the running state so that the configuration cannot be performed 4 Input the password 123456 5 The prompt appears 11 2 3 Interpretation and samples of commands After correctly entering HyperTerminal the following commands can be input help help command boot Startup comm...

Page 52: ...e subnet mask of the agent Normally it is used to set the mask Query Simple input setmask Modify input setmask To change to 255 255 255 0 simply input setmask 255 255 255 0 setgate Query and modify the gateway address of the agent In the case of trans segment the command is used to set gateway Query Simple input setgate Modify input setgate To change to 192 168 0 1 simply input setgate 192 168 0 1...

Page 53: ...the password ipcfg to query the IP address of the current equipment Unlock finished IP address 192 168 0 168 ipcfg 192 168 0 102 to modify the IP address of the current equipment Unlock finished Set IP address 192 168 0 102 Erase block at 0x23c0000ok The IP is saved setbaud to query the current baud rate Unlock finished Baud Rate 19200 setbaud 1 unnecessary to be set normally to modify the current...

Page 54: ...ved setmask to query the current mask Unlock finished Net Mask 255 255 255 0 setmask 255 255 255 0 to modify the current mask Unlock finished Set Net Mask 255 255 255 0 Erase block at 0x23c0000ok The Net Mask is saved setdevip l to query the IP address of the PC on the console Unlock finished The IP of devices 1 is 192 168 000 018 The IP of devices 2 is 192 168 000 112 The IP of devices 3 is 010 0...

Page 55: ...P of devices 3 is 010 010 000 018 yes no y The IP of devices 4 is 010 010 000 112 yes no y The IP of devices 5 is 010 010 000 113 yes no y The IP of devices 6 is 010 010 000 165 yes no y The IP of devices 7 is 192 168 000 165 yes no y The IP of devices 8 is 255 255 255 255 yes no y The IP of devices 9 is 255 255 255 255 yes no y Erase block at 0x23c0000ok The IP is saved boot Input the command boo...

Page 56: ...ation system for entering into Ethernet network management mode Default of IP address 192 168 0 253 Default of gateway 192 168 0 1 Default of mask 255 255 255 0 Chapter 12 Typical Networking Scheme AMX32FE AMX32FE DDN PSTN Network Management Monitoring Ethernet VOICE LAN PBX V 35 IP Gateway E1 LAN Ethernet LAN Host Internet IP FXS FXO Monitoring Equipment Router ...

Page 57: ... with signal ground while the 22nd 24th 26th 28th 30th 32nd 34th and 36th pins are not connected and are to be connected with the 1st 19th and 37th pins if grounding is required DB37 pin and the 1st 19th and 37th pins in 75Ω coaxial adapter shall be connected with signal ground Chapter 13 DB37 RJ45 120Ω Pin Definitions RJ45 Socket 1 2 3 4 5 6 7 8 Attention Operation and maintenance of network equi...

Page 58: ...Access Multiplexer with Fast Ethernet User Manual 57 ...