Access Multiplexer with Fast Ethernet
User Manual
31
ON
ON
2 V.35 clocks in anti-phase
ON
ON
2 V.35 master clocks
ON
OFF
The 1
st
V.35 clock in
anti-phase
ON
OFF
OFF
ON
2 V.35 external clocks
OFF
ON
The 2
nd
V.35 clock in
anti-phase
OFF OFF
Neither of the two V.35
clocks in anti-phase
OFF OFF 2 V.35 slave clocks
III) When 4×RS422/485 interface board is plugged in, the switch is used
for option of RS422/RS485.
1 (The 1
st
Interface)
2 (The 2
nd
Interface)
3 (The 3
rd
Interface)
4 (The 4
th
Interface)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
RS485
RS422
RS485
RS422
RS485
RS422
RS485
RS422
IV) When 2M Ethernet interface board is plugged in, the switch is used
for setting up watchdog and speed of Ethernet interface.
The 1
st
Switch
ON
Watchdog Disabled
OFF
Watchdog Enabled
The 2
nd
Switch
The 3
rd
Switch
The 4
th
Switch
Ethernet Setup
ON
ON
ON
Auto Negotiation
OFF
OFF
OFF
10M, Half-Duplex
OFF
ON
OFF
10M
,
Full-Duplex
ON
OFF
OFF
100M, Half-Duplex
Summary of Contents for AMX32FE