B-1
INSTALLATION
B-1
TECHNICAL SPECIFICATIONS
INPUT
– SINGLE PHASE
Standard Voltage / Phase / Frequency
220V (±10%) / 1 / 50/60 Hz
Rated Max. Input Power
8.1 kW (MMA mode)
6.6 kW (GTAW mode)
Recommended Fuse or Breaker Size (Super Lag or
‘D’ curve)
16A
MMA
Rated Maximum
Supply Current
34 A
Max. Effective
Supply Current
15 A
GTAW
27 A
14 A
RATED OUTPUT
– DC ONLY
Welding Mode
Duty Cycle
(1)
Amperes
Volts at Rated Amperes
INPUT 1~220V
MMA
20%
60%
100%
170A
98A
76A
26.8V
23.9V
23V
GTAW
25%
60%
100%
200A
129A
100A
18V
15.2V
14V
OUTPUT RANGE
INPUT POWER
Welding Mode
Welding Current
Range
Open Circuit
Voltage
Welding Voltage Range
1~220V
MMA
10A ~ 170A
68V
13V (VRD)
20.4 V ~ 26.8V
GTAW
10A ~ 200A
10.4 V ~ 18V
OTHER PARAMETERS
Machine
Power Factor
Efficiency
Protection Class
Insulation Class
arcweld
®
TIG 205 DC
0.73
80% (MMA)
78% (GTAW)
IP23S
F
PHYSICAL DIMENSIONS
Machine
Length
Width
Height
Weight
arcweld
®
TIG 205 DC
455mm
185mm
335mm
11Kg
(2)
Temperature Range
Operating Temperature Range
-10°C ~ +40°C(14°F~104°F)
Storage Temperature Range
-25°C ~ +55°C(-13°F~131°F)
(1) Based upon 10 minute time period (i.e., for 60% duty cycle, it is 6 minutes on and 4 minutes off)
(2) Power Source only.
Note: The above parameters are subject to change with the improvement of machines.