PoE network equipment must be CE marked for use in European Community. Note that the cameras are 
designed for use with indoor network cabling only. 

Camera Location and Environment 

AV2100, AV3100 and AV3130 cameras are intended for indoor use only. Operating ambient temperature 
is 0

º

C to 50

º

C. 

 
If used outdoors the installation requires an appropriate enclosure to protect the camera. 

Camera Mounting 

Cameras are mounted using a ¼” x 20 threaded hole at the bottom of the housing. When mounting the 
camera make sure the screw that goes into the hole is short, ¼” or less, and does not touch the camera 
board. 
 
The camera is to be installed according to the applicable code. The mounting means should be adequate for 
mounting a 1 lb camera plus the weight of the lens. 

Camera Power Supply 

AV2100 and AV3100 cameras should be powered from 9V to 12V DC power source providing at least 4W 
per camera. AV3130 requires 5W. 12V – 1A is recommended. Alternatively, the cameras can be powered 
over Ethernet with 48V. A UL-approved isolated supply is required for use in the US. In the European 
Community the power supply must meet the requirements of the Low Voltage Directive and be CE marked. 

Camera Optics 

A wide variety of C/CS mount ½” lenses may be used with AV cameras. Note that some CS lenses and all 
C-mount lenses may require an adaptor ring. Our lens suggestions include: 

 

Tamron 12FM04T (4mm), 12FM06T (6mm), 12FM12T (12mm) 

 

Fujinon DF6HA-1B (6mm), HF9HA-1B (9mm), HF12.5SA-1 (12.5mm), CF12.5HA-1(12.5mm) 

 

Computar M0814-MP (8mm), M1214-MP (12mm), H3Z451CS (varifocal 4.5-12mm) 

Auto-Iris Lenses 

Standard DC auto-iris lenses can be used with AV2100 and AV3100 cameras equipped with the auto-iris 
feature. Arecont Vision recommends high-resolution optics. Our suggestions for auto-iris lenses are: 

 

Computar HG3Z4512FCS (varifocal 4.5-12mm) 

 

Tamron 12FG04T-SQ (4 mm), 12FG06T-SQ (6 mm) and 12FG12T-SQ(12mm) 

Camera Installation 

1.

 

Attach optics and connect power supply to cameras 

2.

 

Connect network cables with RJ45 connector to the camera LAN port 

3.

 

Connect cameras to a dedicated 100 Mbps network switch. Connect the network switch to a computer 
network adaptor. Arecont Vision recommends that no more than 8 cameras should be connected to a 
single computer. Larger installations should use multiple 8-camera clusters. All clusters can then be 
accessed from a single computer using Remote Access feature described later in this manual 

4.

 

Optionally, for highest video rate performance, configure computer network adaptor for a HALF 
DUPLEX operation. For the best system performance use two network adapters: one for video traffic 
and one for the connection of the computer/server to LAN. It is also recommended that network 
adapter connected to the cameras be configured for a fixed IP address. 

5.

 

Check that the yellow LED on the back of the cameras is on. This LED indicates that a link to the 
router has been established. The green LED will blink when camera is accessed 

Summary of Contents for AV2100

Page 1: ...DISCLAIMS ALL WARRANTIES WITH REGARD TO THIS SOFTWARE INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS IN NO EVENT SHALL ARECONT VISION BE LIABLE FOR ANY SPECIAL INDIRECT OR CONSEQUENTI...

Page 2: ...ation 4 Camera Reference 5 Introduction 5 Connectors 5 Power 5 Housing and Mounting 6 Network Cabling 6 Optics 6 Using a Manual Iris Lens 6 Using an Auto Iris Lens 6 Monitoring Iris Status with AV Vid...

Page 3: ...king a picture of the scene in question Photo Save and attaching it to the email Checking software and camera firmware version About Execute Settings Dump and attach file named LocalMachine ini from t...

Page 4: ...e an adaptor ring Our lens suggestions include Tamron 12FM04T 4mm 12FM06T 6mm 12FM12T 12mm Fujinon DF6HA 1B 6mm HF9HA 1B 9mm HF12 5SA 1 12 5mm CF12 5HA 1 12 5mm Computar M0814 MP 8mm M1214 MP 12mm H3Z...

Page 5: ...mat using TFTP protocol All cameras feature Automatic exposure Automatic multi matrix white balance 50 60Hz flicker avoidance Programmable brightness saturation gamma sharpness windowing and decimatio...

Page 6: ...sharp mega pixel resolution images you should a use a mega pixel resolution lens b obtain best resolution and depth of focus by having the iris slightly closed You should use a manual iris lens whene...

Page 7: ...ansmit network packets To ping a camera in Windows 1 Open a command line interface window click the Start button choose Run enter cmd and click enter 2 For a camera with IP of 192 168 0 100 enter ping...

Page 8: ...hen using auto iris with AV2100 it is also suggested using a ferrite common mode choke Fair Rite 0444164281 with 1 turns place on the auto iris lens cable three centimeters from the lens Related Docum...

Page 9: ...ave a duration of the greater of i the remaining Warranty Period in the original warranty that was applicable to the original Product extended by the time elapsed between AV receiving notice of the no...

Page 10: ...of performance by AV shall be excused to the extent that performance is rendered commercially unreasonable by acts of God war fire flood riot power failure embargo material shortages strikes governmen...

Reviews: