Argent Data Systems
26 |
copied to the device, it can be installed using the
loadfw
command. All applicable updates will be
installed. To load firmware on the network co-processor only, use the
wifi
load
command.
Avoid powering off or resetting the device during the update process. If the main firmware
update is interrupted it will resume as soon as the device is powered up again, but the device may
take several seconds to complete the update. Be sure to allow it enough time to complete before
turning it off again. The network co-processor will also attempt to recover from an interrupted
update, but this process may take several minutes.
Disassembly
It should not be necessary to open the tracker’s case in the course of normal operation, but you
may need to open it to replace the real-time clock battery or to set the safe mode jumper.
To open the Tracker4’s case, remove the four case screws from the rear panel and the two hex
screws from the DE9 connector on the front panel. The circuit board will pull out from the rear of
the case.
The real-time clock battery is a CR2032 type and should last several years. To replace it, simply
push it out of its holder and slide the new one in, positive side up.
The safe mode jumper is located to the left of the center of the board. Short the two pins before
powering up the tracker to force entry into safe mode.