Subject to change_RPERX3-06_14095_1en_03/2022
Page 10
www.argo-hytos.com
4.4 Basic technical parameters
Parameter
Unit
Value
Nominal valve size
DN 06
Maximum operating pressure at ports P, A, B
bar (PSI)
350 (5076)
Maximum operating pressure at port T
bar (PSI)
100 (1450)
Maximum flow volume through the valve
l/min (GPM)
60 (15.9)
Pressure drop
bar (PSI)
graph ∆p = f (Q)
Fluid temperature range NBR
°C
-30 … +70
Max. switching frequency
1/h
15 000
Switching time ON at
ν
= 32 mm
2
s
-1
ms
AC: 30-40
DC: 30-50
Switching time OFF
ν
= 32 mm
2
s
-1
ms
AC: 30-70
DC: 10-50
Working fluid kinematic viscosity range
mm
2
s
-1
10 to 400
Minimum required working fluid purity
class
21/18/15 ISO 4406
Lifetime
cycles
10
7
Valve weight with manual lever control
with 1 solenoid
kg (lbs)
3.11 (6.86)
with 2 solenoids
kg (lbs)
4.56 (10.05)
Technical data of manual lever control
Lever length
mm
102
Lever deflection angle (working)
°
±12 to 20
Control force at the end of the lever
N
40
Technical Data - Solenoid for use in explosive atmospheres
Voltage type
AC 50 / 60 Hz
DC
Available nominal voltages UN
V
110, 230
12, 24, 48, 110
Supply voltage fluctuations
±10 % U
N
Available nominal input power (coils)
W
10
Duty cycle
100 % ED
Electrical protection IP according to EN 60529
IP66 / IP68*
Ambient temperature range for each surface temperature class T4, T5, T6
Temperature class
Nominal coil input power
°C
Ambient temperature range
T4 – 135 °C
10 W
-30 … +70
T5 – 100 °C
10 W
-30 … +55
T6 – 85 °C
10 W
-30 … +45
*IP68 – test conditions: product submerged 1m under water for 1 hour.
The valve is designed for common hydraulic working fluids:
› mineral oils of performance classes HM and HV according to ISO 6734-4
› non-flammable and difficult to ignite hydraulic fluids according to ISO 12922
› environmentally acceptable hydraulic fluids according to ISO 15380
NOTICE:
NBR seal material is not suitable for some working fluid groups, such as the HFD group.
In case of uncertainty, we recommend to perform a test of the mutual tolerance of the seal material and the working fluid.
4.5 Working fluid
Characteristics
measured at = 32 mm
2
/s (156 SUS)
4.6 Valve characteristics
(1160)
(
0)
174
(
0)
58
(
0)
522
(2900)
(
0)
406
80
160
40
360
0 20 30 40 50 60
(2.6) (5.3) (8.0) (10.6) (13.2) (15.9)
0 10
1
2
3
200
240
280
320
120
(
0)
232
(3
0)
48
(4
0)
64
5
5
1, 2, 3, 4
1, 2, 3, 4, 5
4
Operating limits (p-Q)
Operating pr
essur
e p [bar (PSI)]
Flow Q [l/min (GPM)]
Ambient temp 70 °C (158 °F), voltage U
n
-10 % (24 V DC), power P
n
10 W
1
2
3
4
5
R30
Z11
Y11
H11, H51
C11
Pressure drop related to flow (
∆
p-Q)
(116)
(
)
174
(
)
58
(290)
(
)
406
8
16
4
0 20 30 40 50 60
(2.6) (5.3) (8.0) (10.6) (13.2) (15.9)
0 10
20
24
28
32
12
(
)
232
(3
)
48
(4
)
64
4
3
2
1
Pr
essur
e dr
op
∆
p [bar (PSI)]
Flow Q [l/min (GPM)]
P
→
A P
→
B A
→
T B
→
T P
→
T
P
→
A P
→
B A
→
T B
→
T P
→
T
Z11
1
1
2
2
Y11 1
1
1
1
C11 3
3
3
4
2
R30 1
1
2
2
H11 1
1
1
2
2
H51
1
2
Summary of Contents for RPERX3-06
Page 2: ...Subject to change_RPERX3 06_14095_1en_03 2022 Page 2 www argo hytos com ...
Page 3: ...Subject to change_RPERX3 06_14095_1en_03 2022 Page 3 www argo hytos com ...
Page 4: ...Subject to change_RPERX3 06_14095_1en_03 2022 Page 4 www argo hytos com ...
Page 21: ...Návod k použití_RPERX3 06_14095_1cz_03 2022 Strana 2 www argo hytos com ...
Page 22: ...Návod k použití_RPERX3 06_14095_1cz_03 2022 Strana 3 www argo hytos com ...
Page 23: ...Návod k použití_RPERX3 06_14095_1cz_03 2022 Strana 4 www argo hytos com ...