17
EG
OPERATION CONTROL PANEL
Unit is turned on/off by pressing
the control button for 5 seconds.
How to use Emix Tank in electric boiler mode
First of all you have to switch on the unit by the main switch
A = automatic mode of operation to be used normally when the Emix tank is connected to the iSeries
0 = off mode
R = electric water heater manually controlled by thermostat (to be used if the iSeries is in maintenance)
Control Panel
Here the front user panel
in case of need, the electrical elements could be managed by the end user exactly as any electrical
water heater; in this case follow the below procedure:
Turn the main switch to
R-position
Set the thermostat to 65°C
Open the screws of
temperature limiter’s lid
When the Emix is electrically connected the red led is ON (stand by).
• To switch on the unit you have to press the push button for 4”; when the red led will turn off and the first green led
from the left (40-45°) will be lighted you have to release the push button; releasing it Emix unit is ON. Any use of the
push button is activated when you release the push black button and not when you press it.
•
Then, when Emix is active, it will indicate the water temperature inside the tank.
•
If you want to setup the water temperature, you have to speedy press and release the push button enough time to
see ON the green LED equivalent to the water temperature you want to set; then please wait five seconds and the
Emix will go back in the working mode status indicating the current water temperature inside the tank.
• Emix is designed to be always ON; in case you want to switch it OFF you have to press for 4” the push button exactly
as you want to switch on, then when the green LED will be switched off and the red LED will be switched ON you
have to release immediately the push button, otherwise the unit will go into the electrical heater configuration (the
blue led will pass from off to on).
1.
Temp. level indicators 40-85 °C
-
when blinking:
0-42.5
47.6-52.5
57.6-62.5
67.6-72.5
77.6-82.5
-
when lit:
42.6-47.5
52.6-57.5
62.6-67.5
72.6-77.5
82.6-87.5
2.
Electric heating
-
when blinking: activated
-
when lit: electric heating is operating
3.
Bacteria desinfection (autom. activation)
-
when lit: water is heated to 60 °C
4.
Standby
-
when lit: device is not operational
5.
Control button
-
when pressed for 5 sec:
device is turned on/off
6.
IR-receiver