Programming Manual
133
Truncate ending
8
Code ID setting
0x00 ~ 0xff ASCII code(1 or 2 bytes)
(default: p)
10
Leading “A”
0: Disable(*)
1: Enable
1
Read
0: Disable(*)
1: Enable
6
Truncate leading
0 ~ 15(default: 0)
7
Truncate ending
0 ~ 15(default: 0)
8
Code ID setting
0x00 ~ 0xff ASCII code(1 or 2 bytes)
(default: U)
33
MicroPDF
(2D model only)
10
Escape sequence transmit
0: None
1: GLI protocol
2: ECI protocol(*)
1
Read
0: Disable(*)
1: Enable
6
Truncate leading
0 ~ 15(default: 0)
7
Truncate ending
0 ~ 15(default: 0)
8
Code ID setting
0x00 ~ 0xff ASCII code(1 or 2 bytes)
(default: RC)
34
EAN.UCC
composite
(2D model only)
11
UCC/EAN 128 emulation
0: Disable(*)
1: Enable
※1: Stand mode: Normally activated with continuous mode. If set as LED “Off”, the scanner
red beam will turn off automatically in case not used, but will turn on again immediately when
scanning bar codes.