PT-90 Mobile Computer SDK Programming Manual
214
TriggerStatus
To get the scan Trigger Key status.
DWORD
TriggerStatus
{
}
Parameters
None.
Returned Values
The returned value 1 indicates that the scan Trigger Key is pressed and 0 indicates that scan Trigger Key is released.
Example
if(TriggerStatus())
AfxMessageBox(_T("scan key pressed!"));
else
AfxMessageBox(_T("scan key release!"));
Requirements
OS Versions:
Windows CE 6.0 or beyond.
Header:
scanapiax.h
Link Library:
scanapiax.lib
Link DLL:
scanapiax.dll
Device:
PT90