Wired/Wireless Smoke detector: (option)

 

 

The Smoke detector is used to detect potentially dangerous smoke emissions in the home. 

Once   the detector detects the presence of smoke as a danger  and  possible Fire  Risk it  will 
transmit an alarm  signal to the control panel and also activate its own integral local sounder.

 

 

Wired/Wireless Combustible Gas detector: (option)

 

 

5  ZONE CONFIGURATION AND EXPLANATION

 

 

 

Zone 7 selected

 

 

The combustible gas detector will  detect potentially dangerous gas  emissions within its 

location.  It should be fitted in any area where  there is  a  possibility or risk of  Gas  Leaks or 
emissions.

 

Once The Combustible Gas  detector detects  unacceptable levels of  combustible Gas  it 

will  transmit an alarm signal to the  Control  Panel and also  activate  its  own  integral  local 
sounder.

 

Wiredless shock/vibration  detector: (option)

 

 

Glass Break detector: (option)

 

 

The glass break detector should be placed at home where   close to glass. When   the glass 

is broken, the detector could detect the particular frequency and then  transmitting an   alarm 
signal to the control panel.

 

 
 
 

 

1     2     3     4     5     6     7

 

 

1:watchdog zone 

0:not a watchdog zone

 

1:exit delay 

0:no exit delay

 

1:entry delay 

0:no entry delay

 

1:24 hours zone 

0:not 24 hours zone

 

1:sounder when alarming 

0:silent when alarming

 

1:armed zone 

0:part armed zone

 

1:sensor in the zone 

0:no sensor in the zone

 

 
 

Zone 1 selected

 

 

2  DESCRIPTION

 

2. 1 The Keypad

 

 

SET 

TYPE

 

H  

M         D

 

 

 
 
 
 

The  above  shows Zone 1  is  Configured to be  a 24  hour zone,  Active  Sounder  when

 

Arming and there are Sensors in this zone.

 

 
 

Zone 2 selected

 

 

 

 

ARMED  ON

 

PART ARMED  ON 
ALARM  ON 
ALARM  FLASH

 

 

= ARMED

 

= PART ARMED

 

= NEW ALARM LOG

 

= ALARM OR COMMUNICATION

 

 *

 

voice

 

 

  9  

 

RF  out

 

 

voice prompt you how to operate 
for every step

 

 

RF transmit for wireless siren

 

 

SET 

TYPE

 

H  

M         D

 

POWER  ON 
POWER  OFF

 

=AC POWER

 

=BATTERY USING

 

voice

 

  0 

 

OG M

 

recording the owner voice/

 

playback the voice

 

Event/Disarm 
Prog 
Del/Sensor

 

Event LOG/Disarm 
Program 
Delete/Sensor check

 

  #   

Press (walk test) or Press 

hold 

up (alarm with/without sounder)

 

The above shows Zone 2 is configured to be a panic zone, Active Sounder when Arming 

and there are Sensors in this zone.

 

Arm 

Manual ARM or PART ARM

 

 

Figure 2:keypad description

 

24

 

Summary of Contents for ZDAS-300

Page 1: ...Luxury Voiced LCD Alarm System USER S MANUAL Model ZDAS 300 Thank you for choosing our panel Please read the manual carefully before fixing it ...

Page 2: ......

Page 3: ...VIEW 1 1 1 Introduction 1 1 2 Basic Principle of Operation 1 1 3 Component Parts 2 1 4 Optional Extra Detectors available 2 2 DESCRIPTION 3 2 1 The Keypad 3 2 2 The LCD Character details and description 4 3 INSTALLATION INFORMATION 9 3 1 The Basic Flow Chart 6 3 2 Registering Key Fobs 7 3 3Registering Sensors 7 3 4 Installing Wired Detector 8 3 5 Checking Registration 8 3 6 Deleting Registered Key...

Page 4: ...s PROG to save using this way can set C S Account in Pry 7 or other private phone No press the registered key fob ESC key to exit To set C S phone number 1 To register Key fobs 2 To register Detectors 3 To set Zone type 4 To set System configuration 5 To set C S phone NO and site code 1 OVERVIEW 1 1 Introduction 1 Blue backup LCD display everything you want to konw about the panel 2 Full complianc...

Page 5: ...the Alarm Signals from the various Detectors It also contains the central Station communicator and By directional Audio Verification mechanism Everything you need to know about the security system is displayed on the panel keypad LCD The zones 24 Hours Armed Part armed Disarmed and the important Messages regarding system status are displayed on the LCD screen See section 2 1 and 2 2 Wireless Remot...

Page 6: ...tect the particular frequency and then transmitting an alarm signal to the control panel 1 2 3 4 5 6 7 1 1 watchdog zone 0 not a watchdog zone 2 1 exit delay 0 no exit delay 3 1 entry delay 0 no entry delay 4 1 24 hours zone 0 not 24 hours zone 5 1 sounder when alarming 0 silent when alarming 6 1 armed zone 0 part armed zone 7 1 sensor in the zone 0 no sensor in the zone Zone 1 selected 2 DESCRIPT...

Page 7: ...ng system status appear on the LCD screen LOG M D H M D 2 2 The LCD Character details and description 2 2 1 The panel LCD screen whole information shows as follows Figure 23 Detector No 2 in zone 3 is low voltage LOG DIS PART ARMED WatchDog M D H M D B When the panel is in the Armed PART Armed mode if the detector such as PIR detects itself being low voltage the panel will sound a beep every secon...

Page 8: ... is transferred to the C S the operator then has access to the customer details address name phone numbers 2 2 2 When the panel is set in the away armed mode the LCD screen will show the following ARMED key holders etc He also has audio access to the premises He can Listen in or Speak to the occupants this will allow the C S operator to request a pre arranged password to confirm the identity of th...

Page 9: ... fob will still be sounder alarm if it is set with sounder alarm 4 9 Access the Control Panel from a remote telephone mobile or land line The Remote Control enables the use of the land line phone or mobile phone to remotely control panel Call the phone number of the line connected to the alarm panel the panel will answer the call after 1 to 8 rings programmable When the panel answers the call ente...

Page 10: ...ows particular detectors in each Zone to be local alarm only or local alarm and transmit alarm information to the C S each detector can be configured differently e g local Alarm only or local Alarm and C S function door bell function or in the case of Key Fob Request Assistance with without sounder How to set the function press Sensor key and appears on the LCD Press registered Key Fob or entering...

Page 11: ...n the keypad a series of appear on the LCD Enter the PIN code or press the Disarm key on a registered key fob and the word Sensor will appear on the LCD Trigger the detector you wish to register the panel will receive the detectors code and the word CODE will appear on the LCD Pressing a numeric key 1 to 8 on the keypad will select the zone you wish to allocate the detector e g Pressing No 3 on th...

Page 12: ...e No 2 detector in Zone 3 If no further actions take place the panel will automatically return to normal state after approximately 30 seconds Otherwise at the end press Dis Arm key on a registered Key Fob to return the panel to normal state 3 8 The Zone Setting and Allocation The alarm system has 8 zones which can be configured depending on your requirements The Factory Default Zone configuration ...

Page 13: ...d PIN code and the word Sensor will appear on the LCD Pressing the key on the Keypad the LCD will show the words Zone type pressing No1 to 8 numeric key to select corresponding zone then pressing the 0 or 1 numeric Keypad to configure all the fields in this zone At the end press the PROG key to complete and save operation By way of example below is configured as follows Zone 7 selected is a Watchd...

Page 14: ...04 20 seconds 02 Entry delay time delay alarm The time is double digit XX The actual time is the product of XX times 5 The initialization value is 06 30 seconds 03 Sounder run time The time is double digit XX The actual time is the product XX times 20 The initialization value is 06 120 seconds 04 Watchdog time The unit time is hours The factory default value is 12hours 05 Watchdog start and stop t...

Page 15: ...is required within 2 5 seconds after transmitting data to the C S the Panel Will receive the SPEAK request from C S If it is not required the panel hangs up automatically ALM phone line cut_off alarm Figure15 The LCD display when the phone line is cut 13 Engineer Option Listen to dial out DTMF 0 NO 1 YES This option will Automatically extinguish when the panel is closed or on the hour Default 0 14...

Page 16: ...e account code using the numeric keypad on the panel this is normally a 4 Digit Code called site code Press Prog key to store the programmed number If no further actions take place the panel will automatically return to normal state after approximately 30 seconds Otherwise at the end press the Dis Arm key on a registered Key Fob to return the panel to normal state 3 12 Deleting Zones How To Delete...

Reviews: