Wireless keypad PU-R
73
8.6
Properties of control devices
The properties required to be configured, while adding a device, are
in bold
.
►Common properties
The common properties of the devices
RBU, PUL-R
correspond to the
common properties of detectors.
►Properties of PUL-R
Partitions indication
– selection of a type and number of local parti-
tions indicated by LEDs of
PUL-R
.
There are following combinations of partitions indication:
Type
Number
Local partitions
1-8
9-16
Global partitions
1-8
9-16
Note: in order to supervise global partitions by
PUL-R
, turn the corre-
sponding option in the properties of WEx 0.
Menu
Configuring
System
WEx 0
‹
Properties
›
1
Common properties
WEx supervision
Global partitions
Sound – activation/deactivation of audible alarm system of
PUL-R
(ac-
tivating indication of alarms).
Properties of strokes – actions performed when the buttons “1” – “9” of
PUL-R
are stroked
2
extendedly.
The list of actions that can be performed by extended strokes of
PUL-R
:
Action
Parameters
Arming of local partitions
Partitions list
Disarming of local partitions
Partitions list
Panic
Partition number
Request about local partitions states Partitions list
Start relay
Number of WEx and relay
number
1
If the right screen button is <Show> instead of <Action>, press it to show the devices tree, after which press the
screen button “Action” occurred at the screen.
2
Extended stroke – push and hold a button until an audible signal occurs.