background image

5

Technical Parameters

Technical Parameters

Rated Voltage

AC110-120V 60Hz

Rated Current

10.2A

Normal Rated Power

1125W

Recommended Power Service

GFCI-Protected 20A

Water Pipe Dimension

½"

Drainage Pipe Dimension

1 1/2" (40mm)

Max. Hot Water Temperature

176°F (80°C)

Recommended Hot Water

149°F (65°C)

Operating Pressure

Max 116 PSI (8 bar / 0.8 mPa)

Recommended Operating Pressure

14.5-72.5 PSI (1-5 bar / 0.1-0.5mPa)

16

EN12764 2004 A1

:

+

AC110 120V 60H

-

z

14a

1500W

14

"L" = Live = Black or Brown

"N" = Neutral = White or Blue

“G"= Earth-Ground = Green or Yellow

22. Ensure the water supply lines for this product has its own dedicated water

shutoff valves installed in an accessible location.

23. Ensure there is enough space and access to connect, adjust or fasten the

various supply lines, waste line and other components.

24. Be sure to check each installation step with this manual to ensure the prod-

uct is installed correctly. The product must be installed with all the feet or sup-

portive legs touching the floor before any use. Leveling the product is an impor-

tant procedure and must be completed on-site – on the installation surface and

final installation position.

25. Always double-check all connections to ensure for proper installation, ten-

sion, and connection, including parts, plugs, hoses, nuts, screws, wires, etc.

26. Only a professional electrician is recommended to work on the high voltage

portions of installation and testing.

27. Electrical service must meet the requirements listed on the components of

the product, listed within this manual, or otherwise advised based on a thorough

analysis of any special circumstances.

28. An electrical protection device for short-circuits, power overloads or incor-

rect voltage must be installed and used in conjunction with this product.

29. This product or any appliance used near this product must be used in con-

junction with a Ground Fault Circuit Interrupter (“G.F.C.I.” or “G.F.I.”) or Resid-

ual Current Device (“R.C.D.”) with a trip current of not greater than 30mAor oth-

erwise required in accordance to local codes.

30. Do not cut or extend electrical wires or power-cord of the product without

the approval of a professional electrician and warranty service representative.

31. Appliances or components with ground or “earth” connections must be in-

stalled and used in conjunction with the product, and connected in accordance

to local codes.

32. The motor must be grounded with wire not less than 14awg (1.63mm-diam-

eter) or otherwise required in accordance to local codes.

33. Check local and national requirements before installing or purchasing this

product.

34. Local standards and codes must be followed and cannot be the responsibil-

ity of the supplier or its distributors.

35. Other electrical components, except the remote control device (optional),

should be kept, located or affixed away from the product, so they cannot fall

into the bath, while in use.

36. Do not disassemble the control panel or computer controller as it is not de-

signed for disassembly. Defects, damages or shock caused by such removal

cannot be the responsibility of the supplier or its distributors.

37. “H” hot (red) and “C” cold (blue) water supply connections and their orienta-

tion are critical to proper function of this product.

38. Ensure the (optional) “H” hot (red) and “C” cold (blue) water hoses will not

touch the floor when this product is fully installed, as it may cause rusting and

possibly weakening of those hoses.

39. Harsh chemicals such as acetone, ammonia or gasoline can possibly dis-

solve or damage portions of this product – do not use such chemicals for clean-

ing or installing this product.

40. Do not stack anything on top of this product, use it for support, or apply any

extreme pressure to critical areas that may cause misalignment or damage;

take special care when moving this product.

Test standard: 

EN 12764: 2004+A1: 2008 
EN 60335-2-60 (Low Voltage Directive 73/23/EEC)   
EN 1111 

Summary of Contents for ARL-084

Page 1: ...Serial Number ARL 084P Whirlpool Installation User Manual...

Page 2: ...English 1 Pneumatic on off switch 7 Air Regulator 2 Waterfall 8 Multiple Direction Water Jet 3 Shower Wand 9 Air Jet 4 Function Selector 10 Drain 5 Hot Cold Water Mixer On Off 11 Overflow Drain Drain...

Page 3: ...2 All measurements are given in Inches Designs and sizes can vary We accept no liability for errors manufacturing tolerance and product changes...

Page 4: ...arning 2 Never lift the whirlpool tub by or apply heavy pressure to the critical parts such as the jet plumbing jets electrical cables hoses and drain hose or similar components General Precautions 3...

Page 5: ...specifications and local building codes should be reviewed by a licensed professional before purchase Installation Precautions 17 It is recommended to install this product in such a way that the criti...

Page 6: ...unction with a Ground Fault Circuit Interrupter G F C I or G F I or Resid ual Current Device R C D with a trip current of not greater than 30mAor oth erwise required in accordance to local codes 30 Do...

Page 7: ...aning the whirlpool features monthly with a whirlpool clean ing solution from your local hardware store Follow the instructions of the whirlpool cleaning solution If not cleaned regularly you may noti...

Page 8: ...tch 7 Drain Switch Fill faucet 3 Handshower 8 Water Jet Suctions 4 Fancet Hot Switch 9 Water Pump 5 Faucet Selector Switch 10 Water Jet Air Bubble Regulator Valve This valve is used to control the amo...

Page 9: ...e hand shower and when you rotate the faucet 90 to the right the water will come out from the waterfall 2 The water temperature is controlled by the hot water faucet H and cold water faucet C If you r...

Page 10: ...Power Receptacle C C H H 9 Test functions Check for leaks Ensure all connections are tight Install access panel 9 10 L Live Black or Brown N Neutral White or Blue G Earth Ground Green or Yellow 7 10...

Page 11: ...9 7 6 Power Receptacle H C Connect any ground connections to your household ground Connect water connections and electrical supply H C 10 9...

Page 12: ...n When you rotate the faucet 90 to the left the water will come out from the hand shower and when you rotate the faucet 90 to the right the water will come out from the waterfall 2 The water temperatu...

Page 13: ...e is used to control the amount of air bubbles in the Water Jet Feature 12 No No 1 7 2 3 8 Waterfall 4 9 Water Jet 5 10 Water Pump 6 11 Water Suction English English Air Regulator Hot Water Supply Inl...

Page 14: ...aning the whirlpool features monthly with a whirlpool clean ing solution from your local hardware store Follow the instructions of the whirlpool cleaning solution If not cleaned regularly you may noti...

Page 15: ...nction with a Ground Fault Circuit Interrupter G F C I or G F I or Resid ual Current Device R C D with a trip current of not greater than 30mAor oth erwise required in accordance to local codes 30 Do...

Page 16: ...s specifications and local building codes should be reviewed by a licensed professional before purchase Installation Precautions 17 It is recommended to install this product in such a way that the cri...

Reviews: