background image

After Installation:

41.

 

Before

 

supplying

 

any

 

power

 

to

 

the

 

product,

 

you

 

should

 

inspect

 

the

 

power

 

cables

 

to

 

ensure

 

the

 

power

 

leads

 

are

 

properly

 

connected.

42.

 

After

 

installation

 

and

 

before

 

starting

 

the

 

product

 

for

 

the

 

first

 

time,

 

you

 

should

 

inspection

 

all

 

the

 

connections

 

to

 

ensure

 

they

 

are

 

properly

 

connected;

 

including

 

parts,

 

plugs,

 

hoses,

 

nuts,

 

screws,

 

wires,

 

etc.

43.

 

After

 

you

 

have

 

fully

 

installed

 

the

 

unit

 

and

 

made

 

all

 

the

 

inspections

 

to

 

ensure

 

the

 

unit

 

can

 

function

 

safely, fully

 

clean

 

the

 

unit

 

inside

 

and

 

out

 

to

 

ensure

 

the

 

unit

 

is

 

ready

 

for

 

usage,

 

and

 

also

 

to

 

check

 

for

 

any

 

potential

 

lose

 

debris

 

that

 

may

 

have

 

fallen

 

into

 

any

 

of

 

the

 

plumbing.

 

After

 

a

 

thorough

 

visual

 

inspection,

 

close

 

the

 

drain

 

and

 

fill

 

the

 

tub

 

up

 

to

 

the

 

overflow

 

drain,

 

submerging

 

all

 

the

 

jets

 

underwater.

 

If

 

any

 

debris

 

floats

 

out,

 

remove

 

it.

44.

 

The

 

whirlpool

 

system

 

will

 

not

 

run

 

unless

 

the

 

water-level

 

sensor

 

is

 

fully

 

submerged

 

underwater.

 

The

 

water-level

 

sensor

 

is

 

placed

 

above

 

the

 

water

 

line

 

of

 

the

 

water

 

jets.

45.

 

Turn-on

 

the

 

whirlpool

 

system

 

and

 

operate

 

it

 

for

 

a

 

minimum

 

of

 

10-minutes.

 

Then

 

turn-off

 

the

 

whirlpool

 

system

 

and

 

without

 

draining

 

it,

 

allow

 

it

 

to

 

sit

 

for

 

a

 

minimum

 

of

 

10-minutes.

 

Now

 

check

 

all

 

the

 

plumbing,

 

pipe

 

works,

 

hoses,

 

joints,

 

threads

 

and

 

any

 

other

 

connections

 

for

 

any

 

leaks.

 

If

 

there

 

are

 

any

 

adjustments

 

made,

 

restart

 

this

 

test

 

and

 

review

 

all

 

the

 

connections

 

again.

46.

 

You

 

must

 

ensure

 

the

 

product

 

works

 

as

 

it

 

normally

 

would:

 

immediately

 

test

 

all

 

functions

 

of

 

the

 

product

 

to

 

possibly

 

find

 

any

 

errors.

 

After

 

testing,

 

place

 

the

 

tub

 

against

 

the

 

wall(s)

 

and

 

seal

 

the

 

wall

 

joints

 

with

 

an

 

acid-free

 

caulking

 

agent

 

and

 

then

 

allow

 

it

 

to

 

cure

 

sufficiently

 

before

 

any

 

further

 

use.

Additional Precautions:

47.

 

It

 

is

 

not

 

generally

 

recommended

 

to

 

use

 

bath

 

oils

 

in

 

whirlpool

 

bathtubs,

 

as

 

the

 

oil

 

residue

 

can

 

stick

 

to

 

the

 

side

 

walls

 

of

 

the

 

tub

 

and

 

plumbing.

 

Clean

 

the

 

whirlpool

 

system

 

after

 

any

 

such

 

uses.

48.

 

It

 

is

 

not

 

recommended

 

to

 

use

 

coarse

 

grain

 

bath

 

salts

 

with

 

the

 

whirlpool

 

function,

 

as

 

it

 

may

 

enter

 

the

 

water

 

pump

 

and

 

damage

 

or

 

cause

 

additional

 

wear

 

onto

 

its

 

internal

 

components.

6

13

Maintenance:

Recommended cleaning the whirlpool features monthly with a whirlpool clean-

ing solution from your local hardware store. Follow the instructions of the

 

whirlpool cleaning solution. If not cleaned regularly you may notice black

 

flakes 

in the bath – if this happens you should clean the whirlpool system.

Consider cleaning the whirlpool system with whirlpool cleaning solution re-

peatedly until the black flakes disappear. Soap scum, hair, dead skin, skin

 

care 

products, oil, grease and/or bacteria can contaminate your whirlpool sys-tem, it 

is important

to clean regularly.

Consider cleaning the whirlpool system using a cup of chlorine bleach (

sodium 

hypochlorite

)

 

and the minimum amount of warm or hot water to activate the

(water-level sensor) whirlpool system, in between regular cleanings with

 

whirlpool cleaning solution. Thoroughly flush and rinse the bathtub and

 

whirlpool system before use. (This is not meant as a substitute for whirlpool

 

cleaning solution)

The drain can be clogged by hair or soap scum and should be cleaned regu-

larly. Cleaning schedule is based off usage conditions; monitor time frame for

 

any slowing of drainage, and then set cleaning schedule.

Poor maintenance, infrequent, or irregular cleaning can cause damage to the

 

faucets or jets. Cleaning schedule is based off usage conditions; generally,

 

more frequent light cleanings are better than less frequent, heavy cleanings.

When cleaning the chrome parts, do not use cleaning compounds or instru-

ments with abrasives or harsh chemicals. Do not try to remove stains with

 

hard 

objects, such as blades or screwdrivers.

When cleaning the acrylic surfaces of the bathtub, use a soft sponge and a

 

detergent without ammonia, acetone or other harsh chemicals, to prevent sur-

faces from getting dulled or damaged.

Dulled surfaces can be refinished with an acrylic polishing compound (follow

 

instructions of polishing compound); first spot test in a non-visible surface

 

area.

Warning:

 The use of cleaning materials other than those recommended by

 

the 

manufacturer can result in damage to the bathtub, whirlpool apparatus, or

 

other hardware. Spot test in non-visible area.

Warning:

 Any service, adjustment or repair is only recommended by an expe-

rienced professional. Only consider a licensed professional for all installation,

 

servicing or repair work.

Summary of Contents for ARL-701

Page 1: ...Serial Number ARL 702 Whirlpool Installation User Manual...

Page 2: ...1 2 3 4 5 9 7 10 8 No ENGLISH 1 Air Regulator 2 Pneumatic Switch 3 Handheld Shower 4 Hot Valve 5 Selector Valve 6 Cold Valve 7 Water Jet Outlets 8 Drain 9 Overflow Drain Fill Spout 10 Water Jet Sucti...

Page 3: ...er Receptacle Hot water 2 7 5 3 9 14 18 Flex Drain Location 6 1 18 5 Actual Drain Cutout Location All measurements are converted from millimeters Designs and sizes can vary We accept no liability for...

Page 4: ...arning 2 Never lift the whirlpool tub by or apply heavy pressure to the critical parts such as the jet plumbing jets electrical cables hoses and drain hose or similar components General Precautions 3...

Page 5: ...specifications and local building codes should be reviewed by a licensed professional before purchase Installation Precautions 17 It is recommended to install this product in such a way that the criti...

Page 6: ...unction with a Ground Fault Circuit Interrupter G F C I or G F I or Resid ual Current Device R C D with a trip current of not greater than 30mAor oth erwise required in accordance to local codes 30 Do...

Page 7: ...aning the whirlpool features monthly with a whirlpool clean ing solution from your local hardware store Follow the instructions of the whirlpool cleaning solution If not cleaned regularly you may noti...

Page 8: ...witch Fill faucet 3 Handshower 8 Water Jet Suctions 4 Fancet Hot Switch 9 Water Pump 5 Faucet Selector Switch 10 Water Jet Air Bubble Regulator Valve This valve is used to control the amount of air bu...

Page 9: ...er temperature is controlled by the hot water faucet H and cold water faucet C If you rotate the H faucet by counterclockwise then the temperature will goes higher And it s in a similar way for faucet...

Page 10: ...e Black or Brown N Neutral White or Blue G Earth Ground Green or Yellow 9 10 Test functions Check for leaks Ensure all connections are tight Install access panel Connect any ground connections to your...

Page 11: ...e Black or Brown N Neutral White or Blue G Earth Ground Green or Yellow 9 10 Test functions Check for leaks Ensure all connections are tight Install access panel Connect any ground connections to your...

Page 12: ...er temperature is controlled by the hot water faucet H and cold water faucet C If you rotate the H faucet by counterclockwise then the temperature will goes higher And it s in a similar way for faucet...

Page 13: ...witch Fill faucet 3 Handshower 8 Water Jet Suctions 4 Fancet Hot Switch 9 Water Pump 5 Faucet Selector Switch 10 Water Jet Air Bubble Regulator Valve This valve is used to control the amount of air bu...

Page 14: ...aning the whirlpool features monthly with a whirlpool clean ing solution from your local hardware store Follow the instructions of the whirlpool cleaning solution If not cleaned regularly you may noti...

Page 15: ...unction with a Ground Fault Circuit Interrupter G F C I or G F I or Resid ual Current Device R C D with a trip current of not greater than 30mAor oth erwise required in accordance to local codes 30 Do...

Page 16: ...s specifications and local building codes should be reviewed by a licensed professional before purchase Installation Precautions 17 It is recommended to install this product in such a way that the cri...

Reviews: