2. TECHNICAL INSTALLATION INSTRUCTIONS FOR THE
INSTALLER
The installation of the grilling plates, must be carried out only and exclusively by
authorized personnel and based on current regulations, according to the regulations of
the country of destination.
2.1. PRELIMINARY INSTRUCTIONS
- These instructions are only valid if the country symbol appears on the device
- The grilling plates must be installed on a counter and at a minimum distance from the
side walls of 150 mm taking into account that both the counter and the walls must be
non-combustible materials and able to withstand a temperature increase of 65ºC
- It will be verified that all the elements that compose the apparatus are perfectly located
and that due to the transport they have not suffered any maladjustments.
2.2. INSTALLATION PLACE
- It must be a completely clean place
- It must be properly ventilated both in the air inlet and in the evacuation of the products
of combustion in accordance with the regulations of each country, placing the appliance
under an extraction hood of at least 500 m3 / h .; Taking into account that if there were
more gas appliances installed, the amount of air required is 10 m3 / h per kW installed.
- It must have the minimum dimensions necessary to place the iron on it complying with
the safety, temperature and combustibility distances.
- The plates should only be installed in a place with sufficient ventilation to prevent the
formation of inadmissible concentrations of substances harmful to health.
- The plates do not require a special fixation, they should be placed directly on the
surface checking that they are level and stabilized
2.3. TYPE OF GAS USED
Unless specified, the devices are regulated for operation with G.L.P. “Butane 28-30 mbar
or Propane 37 mbar”, this information is indicated on the rating plate that is located on
the left side of the appliance next to the gas inlet.
To adapt them to natural gas, it will be necessary to change the injectors and the rubber
holder, according to section
2.5 CHANGE OF THE TYPE OF GAS.
16