8
Tensor
3.4
Performance data
3.4.1
Actuator specifications
3.4.2
Specifications I-ACT (PMR)
Protection class
IP65 (IP 66/IP 67 Option)
Motor
•
Supply: 85...265 V AC, 50/60 Hz
•
Protection: Primary 2A Tr
•
Control: BLDC
•
50/60Hz ±5%, 100% ED
•
Isolation class E acc. to DIN EN 60034-1
Connection
3 cable entries M16x1.5 (customer provided)
Path cutoff
Digital via magnet sensor
Ambient temperature
-15 °C up to +60 °C
Installation position
Arbitrary
Potentiometer (Option)
Electronic
Travel
10°…100 revolutions
Function group flash controller, DSP functions
System resolution
12 bit
Set value input
Current input max. 0...20 mA, burden 250 W
Voltage input adjustable 0...5 V or 0...10 V
Limited protection against overload and reverse polarity
Actual value transducer
Magnetic position sensor upon basic board
Actual value output
4...20 mA, 0...20 mA, galvanically isolated
Burden max. 500 Ω, Output stroke max. 10 V
Burden 250 Ω, Output stroke 0...5 V
Operation
3 buttons: Left / MENU / Right
1 switch: AUTO / MANU
Status display via two 7 segment displays
Configurable parameters
End position left and right
Set value input: 0/4/20/free values [mA] or 0/5/10/free values [V]
Actual value output: 0/4/20/free values [mA] or 0/5/10/free values [V]
Switch-on and switch-off hysteresis
Speed reduction
Fault message output on/off