35
Tensor
2
6.4
Performance data
The maximum surface temperature of the actuators with regard to an ambient temperature of +50 °C is +80 °C.
Protection class
IP65
Motor
•
Power supply: 85…265 V AC, 50/60 Hz; 19.2…28.8 V DC
•
Type: BLDC
•
Duty cycle: 100% ED
•
Isolation class E acc. to DIN EN 60085
Cable glands
ATEX-certified glands acc. to required protection class, e.g.:
WISKA Hoppmann & Muslow GmbH, Type ESKE/1-e 16
EU type examination certificate no.: PTB 13 ATEX 1015 X
Ø Cable min. 4 mm, Ø Cable max. 9 mm
Position feedback
Digital magnet sensor
Ambient temperature
-15 °C up to +50 °C
Installation position
Arbitrary
Potentiometer (Option)
Electronical
Travel
28°…100 revolutions
Only fixed installed cables and wires in combination with ATEX-certified cable glands are
allowed to be inserted to the actuator. Pay attention to the manufacturer´s references.
The operator must guarantee an appropriate strain relief.
If an error occurs: Dangerous voltage when the protective conductor is NOT connected.
Possible electric shock!
•
Connect the protective conductor terminal (s. symbol in actuator enclosure) with
the protective conductor
at any time
.
•
Do only put the actuator in operation with connected protective conductor!
Explosion hazard
!
The actuator is only allowed to be used if the cover is closed properly and cable entries are
closed.
ADVICE
!