The switch operates with two installed power supplies. At least one power supply must connect to a
power source. Two circuits provide redundancy protection.
displays the location of the
power supplies on the rear panel of the switch.
Important:
Read all installation instructions before connecting the system to the power source.
Lire toutes les instructions d’installation avant de brancher le système à la source
d’alimentation.
•
Non-Redundant Configuration: Connect power to either of the two power supplies.
•
Redundant Power Supply Configuration: Connect power to both power supplies.
•
Power down the Switch: Remove all power cords and wires from the power supplies.
Important:
This equipment must be grounded. Never defeat the ground conductor.
Cet équipement doit être mis à la terre. Ne jamais modifier le conducteur de terre.
Important:
This unit requires overcurrent protection.
Cet appareil requiert une protection contre les surintensités.
4.2.1
AC Power Supplies
The following AC power supplies are supported.
•
PWR-1600AC
displays an AC power supply, including the power socket on the right
side of the module. The AC power supply connects to a circuit that provides the required power, as
specified by
Table 1: Switch Specifications (Dimensions and Weights)
.
Figure 15: AC Power Supply
1 Handle
3 Release
2 Status LED
The power supplies require power cables that comply with IEC-320. The accessory kit provides two
IEC-320 C13 to C14 power cables.