Maintenance and Field Replacement
Note: The Power Supply status LED should be a steady green for normal operation.
6. Verify the new power supply operation by issuing the
show environment power
command.
E.3
switch#
show environment power
The output of the command will list the power supplies in operation and should include the one
you
replaced.
Note: Hot swap fans within 30 seconds to prevent the switch from overheating. Ensure that the
module you are replacing matches those already installed in the switch.
E.3.1 Removing a Fan Module
The following steps are required when removing or replacing fans from a switch.
1.
Ground yourself with an ESD wrist strap.
2.
Push the fan module release lever and slide the fan module out of the switch (
Figure 31: Removing Fan Module
1 Release Lever
E.3.2 Installing a Fan Module
You must make space for installing the fan module by removing an existing one (
1.
Remove the replacement fan from its packaging.
41
Fan Modules