Quick Start Guide: 7368x Series Modular Data Center Switches
Supervisor Module
Appendix F: Maintenance and Field Replacement
F.3.2
Installing a Fan Module
You must make space for installing the fan module by removing an existing one (
Step 1
Remove the replacement fan from its packaging.
Step 2
Slide the new fan module into the switch until the module is fully seated and the release lever
snaps into place.
The fan installation indicator will be green when the fan is installed and seated correctly.
Step 3
Verify that the fan module is working normally.
Note
The fan module status LED should be a steady green for normal operation.
F.4
Supervisor Module
The supervisor module is accessible from the front of the switch as shown in
. Refer to
for more details on the removal and replacement of a supervisor module.
Note
Supervisors are hot-swappable. The switch will reboot when the replacement supervisor powers up.
Figure F-4: Supervisor Module Maintenance
F.4.1
Removing Supervisor Module
Perform the following steps to remove the module.
Step 1
Put on a grounded ESD strap.
Step 2
Lift the supervisor module ejector latch and move the latch down to release the supervisor
module.
Step 3
Gently remove the supervisor module by pulling outwards.
1
Fan Module Release Lever
Summary of Contents for 7368X Series