Quick Start Guide: 7000 Series 2 RU Data Center Switches
Two-Post Rack Mount
Chapter 3: Rack Mounting the Switch
Figure 3-2: Improper Bracket Mount Examples for Two-Post Rack Mount
3.1.1
Attaching Mounting Brackets to the Chassis
This procedure attaches mounting brackets to the switch chassis (
Figure 3-3
).
Step 1
Align the mounting brackets with the attachment pins to obtain the desired mounting position.
Step 2
Place the bracket flush on the chassis with attachment pins protruding through key-openings.
Step 3
Slide the bracket toward the front flange until the bracket clip locks with an audible click.
Figure 3-3: Attaching the Mounting Brackets to the Switch Chassis
To remove the mounting bracket from the chassis
, lift the front edge of the mounting bracket clip
with a flathead screwdriver and slide the bracket away from the front flange (opposite from the
installation direction).
3.1.2
Inserting the Switch into the Rack
This procedure attaches the switch to the rack (
Figure 3-4 on page 11
).
Step 1
Lift the chassis into the rack. Position the flanges against the rack posts.