4.5 A8EPUA Hybrid Station Unit 

 

 

 

 

 

Chart 4-6 Expansion Unit (A8EPUA) 

 

 

 Description: 

1

R2

 

connect to A8MBUA

 

2

EPU

connect to Mother Board Unit 

3

ST9~ST16

station port 

4

CO3~CO4

co line port 

5

connect to Caller ID 

Summary of Contents for AV-20

Page 1: ...12 3 2 Special Demand for Installation Environment 12 3 3 Equipment Remarks 12 4 AV 20 PCB Cabinet Layout 13 4 1 System Inter circuit Layout 13 4 2 A8PWUA Power Board Unit 14 4 3 A8UPSA Power Failure Unit 15 4 4 A8MBUA Mother Board Unit 16 4 5 A8EPUA Hybrid Station Unit 18 4 6 A8VSCA Voice Service Card 19 4 7 A6RSCA RS232 Card 20 4 8 A6MFCA Multi function Card 21 4 8 A6MFCA Multi function Card 22 ...

Page 2: ... Best in Telecommunications 2 5 9 Installation of Multi function Sensor 32 5 10 Multi function Relay Door Switch Installation 33 5 11 Installation for External Paging 34 5 12 Installation of External Music Sources 35 5 13 RS232 SMDR Installation 37 ...

Page 3: ...ct directly either a key phone or SLT according to your requirements The key telephone can display caller ID function for incoming call follow up In addition the Aristel Aristel Aristel Aristel AV AV AV AV 20 20 20 20 is equipped with complete peripherals such as RS 232 for data output door phone multi function sensor multi function relay external music sources external paging voice auto attendant...

Page 4: ... lines other peripherals are independent one another Built in Voice Auto Attendant optional CO station lines connected by RJ 11 and other connections by quick connectors 1 3 System Software Default ROM Operate RAM Software Protection Watch Dog Power Failure Build in Li Battery Call Split Protection Link Maintain Extension Error Action Protection Auto Release 1 4 Safety Conformation Line Short Circ...

Page 5: ...ternal mounting is required Aristel Aristel Aristel Aristel AV 20 Basic Capacity Expansion Capacity Maximum Capacity Co Line 2 2 4 Key Phone 8 0 8 0 16 0 Extension SLT 0 8 0 8 0 16 Door Phone 0 2 2 Relay Switches 0 2 2 Sensor Interfaces 0 2 2 Fax Monitor 0 1 1 Auto Attendant 0 1 2 1 2 RS232 for SMDR 0 1 1 UPS Interface 0 1 1 Speed Dial 1000 0 1000 Power Failure Transfer Phone PFT 2 2 4 Table 2 1 t...

Page 6: ...r Phone 0 5W System Power Back up Battery 7AH 3 4 hours Outgoing Dialing Tone Pulse Dialing Signal Intercom Dialing Tone Pulse Digital Co Line Maximum 1 5K Key Telephone Maximum 40 SLT Maximum 400 Door Phone Maximum 40 Loop Resistance External Paging Maximum 800 Co Line 2 wires External Music Source 2 wires Key Phone 4 wires Relay 2 wires SLT 2 wires Sensor 2 wires Door Phone 2 wires Fax 2 wires W...

Page 7: ...4 88 Key Phone Dimension mm 200 180 75 Working Temperature 0 45 Working Humidity 10 90 non condensing Switch Mode SDM Space Division Matrix Control Mode Stored Program Control SPC Table 2 2 Electric standard for System These specifications were made in 2003 and are subject to the change without notice The products specification list is subject to market changes and the actual specification should ...

Page 8: ...ircuit Protection OHCA Add HFBA Add HFBA Add HFBA Add HFBA Handsfree Conversation Add HFBA Add HFBA Add HFBA Add HFBA One touch Paging Last Number Redial Built In Calculator Dual Color Tri Status LED 8 Key 8 Key 25 Key 25 Key Individual Speed Dial 20 sets 20 sets 20 sets 20 sets Different Ringing Frequencies 9 Kinds 9 Kinds 9 Kinds 9 Kinds Table 2 3 Key Phone Specification These specifications wer...

Page 9: ... interface Expansion Card AV 20 Voice Service Card A8VSCA 1 voice channel 60 seconds Optional Card AV 20 Caller ID Card A8CIDA supports FSK DTMF 1 channel per card Optional Card AV 20 Voice Service Card A6VSCA 2 voice channel 60 seconds Optional Card AV 20 RS 232 Card A6RSCA SMDR Serial Port Optional Card AV 20 Multi function Card A6MFCA 2 door phones 2 relays 2 sensors Optional Card KP Series Tel...

Page 10: ...emind Intercom Hybrid Coding Night service Dialing Signal Confirm Conversation Listening Notice for Busy SLT Direct Inward System Access DISA Door Lock Supervision Door switch Conversation Break Off Maintenance System Data Resetting Programs Index Hold Absolute Hold Fax Monitor Flash time setting Internal External Line Ringing Setting 9 different ringing frequencies Fire Alarm Break Off Alarm Exte...

Page 11: ...Fulfilling SLT s Multi function Tone Pulse SLT Message Setting Telephone Directed Selected Auto Transfer Clear of on hold SLT Direct Dialing for Intercom System Speed Dial Personal Speed Dial Group Station Message Details Report SMDR Door Pone Setting System Data Printing Message information Setting Manual Auto Service Optional Remote Maintenance Internal External Directly Dial Function Setting Li...

Page 12: ...Call Internal Dialing Busy Hold Day Night Service Extension Directly Transfer Function Station to Attendants Dialing Do Not Disturb Conferencing selected Door Switch Control Door Phone Answers External Line Flash Hands Free Dialing System Supervision Conferencing Off Hook Call Announcement External Number Display Pick up Answering Paging Left Leaning water leading speaker port Rotary Wall Mount Ho...

Page 13: ...nal Line Auto hunting Special Line Setting Auto redial Surroundings Listening Baby Listening One touch Function Operations Built In Calculator Function 25 Buttons LCD Phone only Dual Color Tri Status LED Account Code One Touch Extension Dialing Folded LCD Display Conversation Listening One touch Paging Pick up Auto Answering Ray Shut Off Control indicates optional function ...

Page 14: ...The location must have adequate ventilation and a temperature range between 0 45o C with a 10 90 non condensing relative humidity The installation site should have sufficient room to mount the KSU along with the necessary connecting blocks and ancillary equipment on a wall The installation site should not be in areas subject to static electricity e g Dry copiers or vibration e g Heavy machinery Th...

Page 15: ...munications 13 4 AV 20 PCB Cabinet Layout 4 1 System Inter circuit Layout Chart 4 1 Inter circuit Layout Description 1 AC power inlet 2 AC power switch 3 Fuse 4 Charge connector for Power fail 5 RS 232 connector D TYPE 9PIN connector 6 Port for multi function card ...

Page 16: ...ons 14 4 2 A8PWUA Power Board Unit Chart 4 2 A8PWUA Power Unit Description 1 ACIN AC power inlet 2 TIN Transformer Inlet 3 TOUT Transformer Outlet 4 F1 Fuse 5 PWR1 connect to A8MBUA 6 UPS connect to A8UPSA Note This board suits for the voltage AC220V 15 50 60Hz 1 1A 0 65A ...

Page 17: ...tel System Installation manual Aristel the Best in Telecommunications 15 4 3 A8UPSA Power Failure Unit Chart 4 3 A8UPSA Un interrupt power supply Unit Description 1 BAT Charge input 2 UPS connect to A8PWUA ...

Page 18: ...ristel the Best in Telecommunications 16 4 4 A8MBUA Mother Board Unit Chart 4 4 A8MBUA Mother Board Unit Description 1 PWR1 connect to A8PWUA 2 PWR2 connect to A8EPUA 3 EPU connect to A8EPUA 4 VSC connect to A8VSCA 5 U15 system program IC ...

Page 19: ...witch off the program protection battery 8 BAT Battery socket for program protection Li battery 3VDC 180mA H 9 MFC connect to A6MFCA 10 BGM Switch for background music 1 2 for internal 2 3 for external 11 MOH Switch for holding music 1 2 Internal music source 2 3 External music source 12 VR Volume control for background music volume adjustment 13 CN2A CN2B connect to Caller ID 14 EXTMP connect to ...

Page 20: ...tel the Best in Telecommunications 18 4 5 A8EPUA Hybrid Station Unit Chart 4 6 Expansion Unit A8EPUA Description 1 R2 connect to A8MBUA 2 EPU connect to Mother Board Unit 3 ST9 ST16 station port 4 CO3 CO4 co line port 5 connect to Caller ID ...

Page 21: ...oice Service Card A86VSCA Description 1 U1 60 Seconds Voice Chip Flash Memory for the 1st Voice Channel 2 SVR1 Variable Resistor To adjust the Playing Voice Volume for the 1st Voice Channel 3 LED1 LED Indicator It will be steady ON whilst the 1st Voice Channel is Operation 4 VSC 20PIN connector connect to VSC of A8MBUA ...

Page 22: ...Male Type for the connection of either PC COM Port or Serial Printer 2 JP4 3 Pins Jumper Selection Tx Pin when connect to PC COM Port Date Transmit from System to PC SYS PC Rx Pin when connect to SERIAL PRINTER Date Receive from Serial Printer to system SYS Serial Printer 3 JP3 3 Pins Jumper Selection Rx Pin when connect to PC COM Port Date Receive from PC to system SYS PC Tx Pin when connect to S...

Page 23: ...S Serial Printer 5 JP1 3 Pins Jumper Selection DTR Pin when connect to PC COM Port Date Transmit from System to PC SYS PC DSR Pin when connect to SERIAL PRINTER Date Receive from Serial Printer to system SYS Serial Printer 6 RSC 26PIN connector connect to RSC of A8MBUA Note 1 If the system s RS232 is connected to PC please make ALL jumpers to be PIN1 PIN2 SHORTED 2 If the system s RS232 is connect...

Page 24: ... connects with the second door phone DOOR1 Build in quick connector connects with the first door phone SEN2 Build in quick connector connects with the second sensor SEN1 Build in quick connector connects with the first sensor SW2 Build in quick connector connects with the second relay SW1 Build in quick connector connects with the first relay 2 MFC 26PIN connector connect with MFC of the A8MBUA ...

Page 25: ...ristel System Installation manual Aristel the Best in Telecommunications 23 4 9 D1CIDC Caller ID Layout Chart 4 10 D1CIDC Caller ID Layout Description 1 CN2 connect with A8MBUA 2 CN1 connect with A8MBUA ...

Page 26: ...tion 5 1 AC Power DC Battery Back up Installation Chart 5 1 AC Power DC Battery Back up Installation Description 1 Input AC Voltage Input AC Current Ampere AC220V 15 50 60hz 1 1A 0 65A 2 Back up Battery 24VDC 3 Power Consumption Max 30W 4 Working Temperature 0 45 5 Working Humidity 10 90 not coagulate ...

Page 27: ...ons 25 5 2 System Back up Battery Installation Description 1 SW1 If 1 2 are short circuit it will protect the program while back up battery works during power fail 2 SW1 If 2 3 short circuit the battery is off Chart 5 2 Program Protection for Back up Battery Installation ...

Page 28: ...allation manual Aristel the Best in Telecommunications 26 5 3 Co Line Wiring This system use 2 Wires for co line below is the wiring method The wiring method of A8EPUA is similar toA8MBUA s Chart 5 3 Co Line Wiring Layout ...

Page 29: ... 4 The Layout of Fax Machine Installation Description 1 Only A8MBUA supplies fax input 2 The fax input will share with Co 2 3 Another SLT can utilize this fax special route in case no fax 4 2 wires for fax machine as shown at above chart Note Fax machine input is a standard input and can connect with a modem ...

Page 30: ...lephone Installation Description 1 This board A8MBUA can connect to at most 8 Key Phone Station 2 ST1 ST8 Key Phone Station Port 3 4 Wires for key phone station as shown at above chart 4 4 Wire RJ11 connector to be used from left to right including BT AR AT BR 5 AT AR is the audio pair AT Transmission Green Color AR Receiving Red Color 6 BT BR is the Data Power pair BT Pole and Data Receiving Blac...

Page 31: ...use 2 Wires for SLT extensions Below is the wiring method The wiring method of A8EPUA is similar toA8MBUA s Chart 5 6 SLT Wiring Description 1 A8MBUA can be installed 8 SLT maximum 2 From ST1 to ST8 3 2 wires are used for SLT wiring from left to right including AR AT The details are as above 4 AT AR 2 wires for SLT non polarity ...

Page 32: ...the system will automatically connect the co1 with the extension in EXT1 and connect co2 with the extension in EXT2 and connect co3 with the extension in EXT9 and connect the co4 with the extension in EXT10 Please note that only SLT can be used during power during unless a backup battery is provided For the details shown as below ...

Page 33: ...for this system A6MFCA must be installed 2 Multi function Card A6MFCA contain 2 door phone inputs 2 relay inputs 2 sensor inputs 3 DOOR1 DOOR2 just for door phone inputs standard 2 wires with non polarity 4 Built in 2 wires are used for this installation For the details of wiring please see above chart for reference 5 Check the setting of system program in Zone 602 ...

Page 34: ...ti function sensor is needed A6MFCA must be installed 2 Multi function Card A6MFCA contain 2 door phone inputs 2 relay inputs 2 sensor inputs 3 SEN1 SEN2 for multi function relay installation standard 2 wires with non polarity 4 Built in 2 wires are used for this installation For the details of wiring please see above chart for reference 5 Check the setting of system program in Zone303 ...

Page 35: ... A6MFCA must be installed 2 Multi function Card A6MFCA contain 2 door phone inputs 2 relay inputs 2 sensor inputs 3 SW1 SW2 just for multi function relay installation inputs 4 This relay can be used to suit your requirement by changing the program Built in 2 wires are used for this installation For the details of wiring please see above 5 For the installation mode please see the chart 6 Check the ...

Page 36: ... Installation for External Paging Chart 5 10 Installation of External Paging Description 1 This system offers a group of external paging zones 2 External paging input EXT PAGE locates on the A8MBUA 3 2 wires are used for external paging For the installation mode please see the above ...

Page 37: ... 12 Installation of External Music Sources Chart 5 11 Installation of External Music Sources Description 1 This system offers external music sources input 2 External music sources input EXT MUSIC locates on A8MBUA 3 2 wires are used For the installation please see the above chart ...

Page 38: ...ce to be Background Music or Music On Hold by Jumper Selection on A8MBUA BGM Background Music selected Internal music resources jump to 1 2 External music resources jump to 2 3 MOH Music on hold selected Internal music resources jump to 1 2 External music resources jump to 2 3 5 Please see the below chart the Details of the Jumper Selection on A8MBUA ...

Page 39: ...Aristel System Installation manual Aristel the Best in Telecommunications 37 5 13 RS232 SMDR Installation Chart 5 12 RS 232 Output Installation ...

Page 40: ...S232 with PC Description 1 Only 1 RS 232 output outlet for this system 2 RS 232 must be installed in the A8MBUA 3 The jumper JP1 JP4 should be confirmed to be in the right place For jump position please see the description of Chart 4 8 A6RSCA RS232 Card Layout 4 Note only pins No 2 6 on RS232 to be used in AV 20 KTS ...

Reviews: