Revised by R. Robinson
Issue AV1.13 8 June 2006
13
Zone 119
DISA CO Time
Default value =
190
Range =
(000 ~ 255) Sec.
(Note! Minimum value of 015 if mult. by 10)
This zone limits the duration of ECF and unsupervised conference calls. The timer can be reset by dialing any
digit except * or #. The * will terminate the call.
extends the timer by a factor of 10.
Related Zones.
, Also ECF, Conference Calls, Func-2-6
Zone 120
AT-RED Wait Time
Default value =
010
Range =
(000 ~ 255) Sec.
If the auto-redial, or save-redial function is activated and the hand piece is not taken off hook before the time
setting is reached, the system will disconnect the CO line. The auto/save-redial function is then placed in Auto
Redial Pause Time status (
), when that timer has been reached, the call will be redialed.
The above sequence will be repeated for the number of times as set in
.
Related Zones.
,
Zone 121
AT-Red Pause Time
Default value =
010
Range =
(000 ~ 255) Sec.
This timer sets the time between CO release and CO re-seizure for auto/save redial.
Related Zones.
,
Zone 122
Busy Rem ICM Time
Default value =
020
Range =
(000 ~ 255) Sec.
When a call (i/c or transferred) is ringing to a busy station, a reminder tone will be heard at intervals set by
this timer. If the station is a 25 Button Keyphone, the tone will be heard from the base of the Keyphone. If the
station is a 15 Button Keyphone or an SLT, the tone will be heard in the earpiece of the handset. Setting this
zone to 000 will stop the Busy Reminder Tone.
This zone also sets the time between rings when a call is recalling from on hold/exclusive hold. If this zone is
set to 000 the station will receive continuous ringing when recalling from hold/exclusive hold.
This zone is also the cfwd on busy timer fro DID calls to busy extensions
.
NOTE! This timer must be shorter than
if DID and call queue is used with voice mail systems
NOTE! The AV8 does not have BRT on SLT extensions.
Related Zones.
,
,
,
Zone 123
In Hunt Ring Time
Default value =
015
Range =
(000 ~ 255) Sec.
If an incoming call is not answered by a free station, the call will be transferred to the next available station in
the same group. If the incoming call is to a busy station, the call will be transferred immediately to the next
free station assigned. This zone sets the time between transfers in a hunt group
Related Zones.
,
Zone 124
Door SensorR Time
Default value =
000
Range =
(000 ~ 255) Sec.
This zone sets the maximum timee that the Door Sensor will ring the stations. 000 disables the ringing.
Related Zones.
,
,