Revised by R. Robinson
Issue AV1.13 8 June 2006
11
Zone 107
Hold Recall Time
Default value =
090
Range =
(000 ~ 255) Sec.
This sets the time which if exceeded, causes the call left in hold to revert to the holding station.
Related Zones.
,
,
Zone 108
Hold Recall Timeout
Default value =
030
Range =
(000 ~ 255) Sec.
If a held call reverts to the holding station and is not answered by the time set in this zone, it will transfer to an
available console in the same console group.
Related Zones.
,
Zone 109
Xhold Recall Time
Default value =
090
Range =
(000 ~ 255) Sec.
This sets the time which if exceeded, causes the call left in Exclusive hold to revert to the holding station.
Related Zones.
,
,
,
Zone 110
Xhold Recall Timeout
Default value =
030
Range =
(000 ~ 255) Sec.
If an Exclusive held call reverts to the holding station and is not answered by the time set in this zone, it will
transfer to an available console in the same console group.
Related Zones.
,
,
,
Zone 111
SLT DT Timeout
Default value =
005
Range =
(000 ~ 255) Sec.
SLT
If the SLT is off hook for more than the set time and no digits are dialed, dial tone will cease and the SLT is
connected to busy tone.
This time may need to be extended when Func 91 is used for modem dialing through a Keyphone
KEYPHONE
If the time set here is greater than 15 Seconds, the On hook functions below will be limited by this time. But if
the time set here is less than 15 Seconds, the On hook functions below will be limited by 15 Seconds.
Pressing [SPK] key without dialing
Pressing [FUNC] key without dialing
Pressing [*] key without dialing
Obtaining C.O. access and not dialing will be limited by the time setting.
Pressing the SPD key without dialing will be limited by the time setting.
Related Zones.
None