Revised by R. Robinson
Issue AV1.13 8 June 2006
12
Zone 112
SLT In-DIAL Timeout
Default value =
015
Range =
(000 ~ 255) Sec.
If the SLT is dialing and the time between any two digits or the time to commence dialing exceeds the time set,
the DTMF receiver releases. This will inhibit the SMDR called number print-out, as well as Access Barring
Related Zones.
,
,
Zone 113
Trf Busy Rc Timeout
Default value =
030
Range =
(000 ~ 255) Sec.
If a call is transferred to a busy station and is not answered by that station within the time setting, the call will
divert back to the original station.
Related Zones.
Zone 114
Trf NoAns Rc Timeout
Default value =
030
Range =
(000 ~ 255) Sec.
If a call is transferred to a free station and is not answered by that station within the time setting, the call will
divert back to the original station.
Related Zones.
Zone 115
CFW NoAns Tr Time
Default value =
005
Range =
(000 ~ 255) Sec.
If a station is programmed for “Call Forward on No Answer”, an incoming or internal call to that station will
be call forwarded after the time setting has been reached.
Related Zones.
,
Zone 116
DISA No Ans Timeout
Default value =
025
Range =
(000 ~ 239) Sec.
When an incoming DISA call is not answered before the time setting is reached, the call will be transferred to
the console assigned in
Related Zones.
,
,
Zone 117
DISA No Dial Timeout
Default value =
005
Range =
(000 ~ 255) Sec.
If an incoming DISA call is answered and no digits are dialed by the caller, when the time setting has been
reached, the call will be transferred to the console assigned in
Related Zones.
,
Zone 118
DISA Delay Time
Default value =
004
Range =
(000 ~ 255) Sec.
The Auto Attendant will answer incoming DISA calls only after the time setting has been reached.
Related Zones.
,