Revised by R. Robinson
Issue AV1.13 8 June 2006
15
Zone 132
(AV256 only) Meter Delay Time
Default value =
000
Range =
(000 ~ 255) *1 Sec.
This timer inhibits the detection of meter pulses until the timer has been reached
Related Zones.
Zone 133
Disa Wait C.
Default value =
015
Range =
(000 ~ 180) *1 Sec.
If a DISA call is transferred to the consoles and all the consoles are busy, the system will recheck the consoles
and a reminder tone will be sent to the consoles at this time. This will repeat until one becomes free or until
four rechecks are made. After four rechecks the call will be released. The call is not COB on the Consoles
Related Zones.
,
,
Zone 134
In Delay Tm
Default value =
010
Range =
(000 ~ 255) *1 Sec.
This timer inhibits selecting a C.O. line for an outgoing call, for the set time, after it has been released from an
incoming call. Ie.: prevents call crashing.
Related Zones.
Zone 135
(First Function) Key Page Tm
Default value =
006
Range =
(000 ~ 255) *5 Sec. (Minimum value = 007. Less than 007 results in 35 seconds)
This timer is the duration that a station will stay in the second page state once the second page button has been
pressed. Pressing the second page button will immediately return the station to the first page state.
Related Zones.
,
Zone 135
(Second Function)
Silent Time for Zone 212
Default value =
060
Range =
(000 ~ 255) *5 Sec. (Minimum value allowed = 007)
This timer sets the period between ringing for a normal SLT using the Message Waiting Function.
NOTE! IF THE EXTENSION CARD IS A SLUC ON AN AV256, A 90 V LAMP/LED CAN BE USED IN
LIEU OF RINGING. THE SLT WILL FLASH DURING THE PERIOD OF THIS ZONE.
Related Zones.
,
,
Zone 136
(First Function) SOS Delay Tm
Default value =
006
Range =
(000 ~ 255) *1 Sec.
If the SOS sensor has been activated, this timer inhibits dialing out until the time has been reached.
To cancel the timer function:- From a console, off-hook, dial # ,5, 5, Password set in
To re-arm:- From a console, off-hook, dial #, 5, 7
Related Zones.
,
,
,
Zone 136
(Second Function)
Ringing Time for Zone 212
Default value =
006
Range =
(000 ~ 255) *5 Sec.
This timer sets the ringing period for a normal SLT using the Message Waiting Function as set by
NOTE! IF THE EXTENSION CARD IS A SLUC ON AN AV256, A 90 V LAMP/LED CAN BE USED IN
LIEU OF RINGING. THE SLT WILL STILL RING DURING THE PERIOD OF THIS ZONE.
Related Zones.