-- 46 --
bu09d12e2
LUD 450/450 W
LUD 450/450 W
Voltage
400V 3
~
50/60 Hz
230/400/500V 3
~
50Hz
208/230/460/475V 3
~
60 Hz
Permissible load at
100% duty cycle
360A / 34,4V
360 / 34,4V
60% duty cycle
425A / 37V
425A / 37V
45% duty cycle
450A / 38V
450A / 38V
Setting range
MIG/MAG
15A/15V (8V)--450A/36,5V
30A/15V (8V)--450A/36,5V
Setting range
MMA
16A / 20V--450A / 38V
10A / 20V--450A / 38V
Setting range
TIG
4A/10V--450A/28V
10A/10V--450A/28V
Open circuit voltage
MIG/MAG
65 -- 80 V
65 -- 80 V
Open circuit voltage
MMA /TIG
50 -- 60 V
50 -- 60 V
Open circuit power
520 W
520 W
Efficiency,
at max current
MIG/MAG
82%
MMA
83%
TIG
83%
MIG/MAG
82%
MMA
83%
TIG
83%
Power factor,
at max current
MIG/MAG
0,92
MMA,
0,92
TIG
0,90
MIG/MAG
0,92
MMA
0,92
TIG
0,90
Enclosure class
IP 23
IP 23
Weight
kg
96/110
143/157
Dimensions
, lxwxh
910x642x835
910x642x835
Application
classification
These welding rectifier conform to the requirements of IEC 974--1.
Duty cycle
The duty cycle refers to the time as a percentage of a ten--minute period that you can weld at a cer-
tain load without overloading the welding power source.
Enclosure class
The
IP
code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked
IP 23
is designed for indoor and outdoor use.
Application class
The symbol
indicates that the power source is designed for use in areas with increased
electrical hazard.
5
INSTALLATION
The installation must be executed by a professional.
WARNING!
This product is intended for industrial use. In a domestic environment this product may cause radio
interference. It is the user’s responsibility to take adequate precautions.
GB