Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Page. 20 di 64
2.3.2 FAST R X/BRD LNX
TEMPERATURE
RANGE
MIN
MAX
35°C
65°C
Variation of the temperature by the knob
SANITARY TAP
The sanitary tap is detected by
water pressure
Gas valve and
spark generator
ON
FLAME CHECK
After dection flame, there is verification of the
current
If the current is not sufficent, there is safety gas
valve shut down.
Modulation occurs between the value of the
maximum power and the value of the minimum
power.
The burner is on till the outlet limit temperature.
The temperature is checked by the outlet
thermostat. During the flow rate variations and
during the ignition the power is managed by the
rod .
Overheater on the heat exchanger (85°C)
F
ON
C
T
IO
N
N
EM
E
N
T
N
O
R
M
A
L