Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Page. 25 di 64
3.1.5 SANITARY FLOWMETER
When there is a sanitary tap, the flow of water passes through the turbine that allows the electronic card to
measure the flow by means of a reed sensor.
The sanitary flow meter is used to detect the tap and also to calculate the power.
Flow rate on: 2 l/min
Flow rate off: 1,5 l/min
3.1.6 TEMPERATURE NTC SENSOR
To check the inlet temperatures, the appliance used immersion NTC sensor, located in the inlet hydraulic
block.
TEMPERATURE (°C)
RESISTANCE (Ohm)
0
23730
10
15450
20
10310
30
7037
40
4905
50
3485
60
2521
70
1853
80
1384
NTC outlet
sensor
Turbine
Reed
sensor