Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Page. 26 di 64
3.1.7 OVERHEAT SENSOR
The overheat thermostat is located on the heat exchanger.
The opening of contact of overheat thermostat (85°C) causes boiler safety shutdown.
To restart the appliance the temperature must be go down the normal operating values of the thermostat
(80°C) and: ON/OFF on the flow rate.
3.1.8 safety fume sensor
Fixed on the right side of the air intake hole by 2 screws.
The safety device is connected in series with the overheater.
Datas:
Cut of temperature: All models: 135°C +/- 4°C
Reactivation temperature: All models: 80°C +10 -12 °C