4.3.1.3 MAX burner pressure setting
1.
Close the gas valve;
2.
Unscrew the screw “a” and insert the manometer
connection pipe into the pipe tap
3.
Open the gas valve
4.
Press “on/off” button the display will show
5.
Press “+” and “-” buttons for 3 seconds, display
shows “PA”
6.
Press “+” button, to select ”PH”. Open sanitary hot
water tap
7.
Press the “on/off” button to access to the “PH”,
appliance is forced to run at max power
8.
On the manometer verify the pressure and if
necessary by “+” or”-” to adjust as indicated in the gas setting table
9.
Press the on/off button to exit from the parameter PH. Close water tap
10.
Press + button to select the
parameter
11.
Press on/off button to save the change
4.3.1.4 min burner pressure setting
1.
Close the gas valve;
2.
Unscrew the screw “a” and insert the manometer connection pipe into the pipe tap
3.
Open the gas valve
4.
Press “on/off” button the display will show
5.
Press “+” and “-” buttons for 3 seconds, display shows ”PA”
6.
Press “+” button, to select”PL”. Open sanitary hot water tap
7.
Press the “on/off”button to access to the “PL”, appliance is forced to run at max power
8.
On the manometer verify the pressure and if necessary by “+” or”-” to adjust as indicated in the gas
setting table
9.
Press the on/off button to exit from the parameter PL. Close water tap
10.
Press + button to select the
parameter
11.
Press on/off button to save the change
4.3.1.5 slow ignition power setting
1.
Close the gas valve;
Summary of Contents for BRD LNX
Page 44: ...Training Manual FAST EVO X FLUENDO PLUS LNX FAST EVO R X BRD LNX Page 44 di 64 ...
Page 62: ...Training Manual FAST EVO X FLUENDO PLUS LNX FAST EVO R X BRD LNX Page 62 di 64 ...
Page 63: ...Training Manual FAST EVO X FLUENDO PLUS LNX FAST EVO R X BRD LNX Page 63 di 64 ...
Page 64: ...Training Manual FAST EVO X FLUENDO PLUS LNX FAST EVO R X BRD LNX Page 64 di 64 ...