Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Page. 38 di 64
4.3.2.3 Setting the maximum burner pressure gas
4.3.2.4 Setting the minimum burner pressure gas
MAXIMUM BURNER PRESSURE (mbar)
G20
G30
G31
11 L
10.5
24,1
31,3
14 L
13,4
27,2
31,3
MINI BURNER PRESSURE (mbar)
G20
G30
G31
11 L
2,2
5,1
6,6
14 L
2,1
4,6
5,9
1. Inlet pressure gas:
b
.*
2. Pressure gas on the burner:
a
3. Removed the batteries before setting
4. Open the sanitary tap.
5. Put the
Switch 1
on ON :
Test
Mode.
6. Put the
Switch 2
ON and
Switch 3
OFF : M
axi Power.
7. Setting the
Orange screw
(see the table).
8. Put the
Switch 1
on OFF :
to exit the mode test.
9. To save the gas setting remove the batteries.