4.3.2.6 modification GAS
To removed the gas diaphragm, and change the appliance to natural gas to GPL (or reverse), you must do:
Change the manifold and diaphragm gas.
Set the micro switchs on the main PCB (see table)
for FAST EVO X or set on display the “PA” for
FAST EVO X DISPLAY.
Check the minimum and maximum burner pressure.
Unscrew the 2 screws that hold the gas valve on the chassis
Unscrew the 2 screws that hold the injector collector
Unscrew the 2 screws that hold the gas pipe
Removed the diaphragme gas