Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Page. 51 di 64
6.1
TROUBLESHOOTING- FAST EVO X/FLUENDO PLUS LNX
6.1.1 Flashing (micro switch not correct)
Single Flashing
(x1)
Micro-switch not in correct
position
6.1.2 Flashing (Temperature sensor out)
Double Flashing
(x2)
T° sensor out
Check the position of the
micro switch with the
instruction booklet
batteries
OK
Check the
water
pressure
Pressure < 0,1 b
Increased the pressure
P > 0,1 b
Pressure
> 0,1 b
Check the curve ot
the NTC sensor
following the table
Replace the NTC
Not correct
Check the wire
of the probe
Replace the probe
Not correct
Correct
Replace the
batteries
Check the wire and replace the
main board if necessary
Check the
batteries
Batteries not OK
Wire
correct
Summary of Contents for BRD LNX
Page 44: ...Training Manual FAST EVO X FLUENDO PLUS LNX FAST EVO R X BRD LNX Page 44 di 64 ...
Page 62: ...Training Manual FAST EVO X FLUENDO PLUS LNX FAST EVO R X BRD LNX Page 62 di 64 ...
Page 63: ...Training Manual FAST EVO X FLUENDO PLUS LNX FAST EVO R X BRD LNX Page 63 di 64 ...
Page 64: ...Training Manual FAST EVO X FLUENDO PLUS LNX FAST EVO R X BRD LNX Page 64 di 64 ...