Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Page. 56 di 64
6.2.3
Ignition but not successful
Ignition but not successful
Insufficient
pressure gas or
not correct gas
Check the gas type and
pressure reducer of the
installation
Electrode
ignition / flame
detection not
OK
REPLACE
Electrode
ignition / flame detection
Overheating
thermostat
work
valve
Decrease gas inlet or
incerase water inlet
Overheating
thermostat
not
work
Fume safety
sensor work
Replace the
batteries
Batteries OK
Check the wire and replace the
main board if necessary
Check the
batter
Batteries not OK
Gas type and
pressure
correct
Electrode ignition /
flame detection
OK
Check inlet gas type
and pressure
Electrode ignition /
flame detection
Check fume system is
fluent
Overheating
thermostat
Fume safety
sensor