2.3 MANAGEMENT OF THE APPLIANCE
2.3.1 FAST EVO X/FLUENDO PLUS LNX
TEMPERATURE
RANGE
MIN
MAX
35°C
65°C
Variation of the temperature by the knob
SANITARY TAP
The sanitary tap is detected by the proportional
flow meter
Gas valve and
spark generator
ON
FLAME CHECK
After dection flame, there is verification of the
current
If the current is not sufficent, there is safety gas
valve shut down.
Modulation occurs between the value of the
maximum power and the value of the minimum
power.
The burner is on till the outlet limit temperature.
The temperature is checked by the outlet NTC.
During the flow rate variations and during the
ignition the power is managed by the T and the
flow rate measure through the proportional flow
met.
Overheater on the heat exchanger (85°C)
The limit temperature is checked by the outlet
NTC sensor:
OFF : 65°C
ON : 60°C
F
ON
C
T
IO
N
N
EM
E
N
T
N
O
R
M
A
L