Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Page. 42 di 64
4.3.3 FAST R X/BRD LNX
4.3.3.1 Supply pressure check
1. Close the gas valve.
2. Loosen
screw “b” and insert the pressure gauge connection pipe into the pipe tap.
3. Open the gas valve.
4. Switch the appliance ON by opening a DHW tap.The supply pressure should correspond to the value
established in relation to the type of gas for which the appliance is designed.
5. Switch the appliance OFF by closing the DHW tap.
6. Close the gas valve.
7. When the check is over, tighten screw “b” and make sure it is securely in place.
8. Open the gas valve and check the tightness of the screw.
4.3.3.2 Checking the maximum pressure (see the Gas setting table)
1. Close the gas valve
2. Loosen screw “b” and insert the manometer connection pipe into the pipe tap.
3. Open the gas valve
4. Open one hot water tap.
5. Turn the knob 1 on MAX position, (Appliance forced to maximum power). Turn the knob 3 turn in central
position.
INLET PRESSURE GAS
GAZ NATUREL
RU
GAZ NATUREL
G 30
13 mbar
20 mbar
29 mbar