Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Page. 55 di 64
6.2 TROUBLESHOOTING-FAST R X/BRD LNX
6.2.1 Flashing (Low voltage)
Flashing
Low voltage
6.2.2 No ignition
No ignition
Change batteries
Check water
flow
Water pressure is
low
Increase water pressure
Check switch
status
turn on or replace switch
switch
position off
or not ok
Check batteries
Replace the batteries
Batteries not OK
Switch
on
Replace the
thermostat
thermos
tat
OK
Check the wire and replace the
main board if necessary
thermostat
Thermostat
not OK
batteries
OK
Water
pressure
normal