Training Manual FAST EVO X/FLUENDO PLUS LNX -FAST EVO R X/BRD LNX
Page. 58 di 64
6.3.2 E3 (igniton failure or flame lift)
E3
Ignition failure or flame lift
Replace the
batteries
Batteries OK
Check the wire and replace the
main board if necessary
Check the
batter
Batteries not OK
Insufficient
pressure gas
Check the pressure
reducer of the installation
Insufficient
pressure gas
Check the pressure
reducer of the installation
Problem on
the safety
valve
Repalce the
gas valve gaz
Safety valve
correct
Ignition proble
simple
Electrode with 2
pin
Check the
position
Gaz pressure
correct
Gaz pressure
correct
Check the static
pressure gaz between
17 et 25 mb natural gas
and 28 et 40 GPL
Check the dunamic
pressure gaz between
17 et 25 mb natural
gas and 28 et 40 GPL
Replace and put the new
electrode with 2 pin
Check the
valve gas
Check the set
ignition and
ionisation probe