6.3.4 E5 (overheat)
E5
Overheat
Check the dynamic
pressure gaz between
17 et 25 mb natural
gas and 28 et 40 GPL
Gas pressure
too hight
Set the pressure reducer of
the installation
Check the maxi power
of the appliance
Bad setting
Set the gas valve following
the instruction booklet
Correct setting
Gas pressure
correct
Check the exhaust
fume
Clean it by a professional